Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: WIRE UP ELECTRICAL CONTRACTING CORP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WIRE UP ELECTRICAL CONTRACTING CORP in 155 WEST 126TH STREET, NEW YORK, NY 10040 (NAICS 238210). OSHA activity number 340052257.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Wire UP Electrical Contracting Corp — free Get an email when a new federal OSHA severe-injury report for Wire UP Electrical Contracting Corp is published. One employer, no account, unsubscribe in one click.
Site address
155 WEST 126TH STREET
City
NEW YORK
State
NY
ZIP
10040
Mailing
4718 NEW UTRECT AVE, BROOKLYN, NY 11219
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
12
Ownership type
A

4 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 4 exposed
Issued
Dec 4, 2014
Penalty
Initial $2,400 · Current $1,000 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    Location: 155 West 126th Street, New York, NY first floor site entry/exit.    On or about 30 October 2114, and again on 31 October 2014.    A). Employees entering and exiting the site on the first floor, were exposed to fall hazards through open floor joists into the basement below because the plywood walk path was not equipped with Guardrails, or safety nets to prevent employees from stepping off the path.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2400
  • — Z (S) $2400

1926.1052 C01

Serious Gravity 5 3 instances 2 exposed
Issued
Dec 4, 2014
Penalty
Initial $2,400 · Current $1,000 Reduced
29 CFR 1926.1052(c)(1)(ii): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with a handrail system along each unprotected side or edge:    On or about October 30, 2014, and again on October 31, 2014.    Location: 155 West 126th Street, New York, NY    a). Employees working on site traversed the west stairs from roof top to street level numerous times daily to complete their work.  Employees were exposed to fall hazards because the stair systems was not equipped with a handrail system along each unprotected side or edge of the stairs.
Recent events (3)
  • — F (S) $1000
  • — C (S) $2400
  • — Z (S) $2400

1926.1052 B01

Serious Gravity 5 24 instances 4 exposed
Issued
Dec 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan.Temporary treads and landings used for pan stairs that were to be filled in with concrete or other solid material at a later date were worn below the level of the top edge of the pan.  On or about October 30, 2014 and October 31, 2014  Location: 155 West 126th Street, New York, NY every stair well throughout the project.  Employees were traversing throughout the project using stairwells and were exposed to trip and fall hazards because the stair landing pans were not filled in with a solid material and the material used to fill stair treads had been worn down below the top lip of the tread pan.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1926.1052 C04

Serious Gravity 5 3 instances 4 exposed
Issued
Dec 4, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1052(c)(4): Employer did not ensure Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were provided between the top rail of the stair rail system and the stairway steps:    On or about October 30, 2014, and again on October 31, 2014.  Location; 155 West 126th Street, New York, NY West structure fourth floor stairway.  a). Employees utilizing stairs to traverse through the project from ground level to the roof, were not protected from falls off the stairs because the stairwells were not protected with midrails, screens, mesh, or intermediate vertical members.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Wire UP Electrical Contracting Corp's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340052257.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.