Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,871Inspections Most recent open 2026-07-30 Last loaded 2026-08-03

OSHA Inspection: RIVES AND REYNOLDS LUMBER CO., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RIVES AND REYNOLDS LUMBER CO., INC. in 950 N. CHURCH, LOUISVILLE, MS 39339 (NAICS 321113). OSHA activity number 340053362.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rives and Reynolds Lumber CO., INC. for free Get an email when a new federal OSHA severe-injury report for Rives and Reynolds Lumber CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
950 N. CHURCH
City
LOUISVILLE
State
MS
ZIP
39339
Mailing
2940 HWY 15 N, LOUISVILLE, MS 39339
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321113
Employees
93
Ownership type
A

2 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 25 exposed
Issued
Feb 24, 2015
Abate by
Mar 11, 2015
Penalty
Initial $2,975 · Current $1,640 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.      a) Sawmill - On or about October 29, 2014, combustible wood dust up to one inch thick had accumulated on the ceiling beams and ceiling fixtures.  The Department of Labor, Salt Lake Technical Center, classified the wood dust as Class II, explosive dust.
Recent events (2)
  • · I (S) $1640
  • · Z (S) $2975

1910.307 C02

Serious Gravity 1 1 instance 25 exposed
Issued
Feb 24, 2015
Abate by
Mar 11, 2015
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1910.307(c)(2): 29 CFR 1910.307(c)(2): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not safe for the hazardous (classified location), nor approved for the hazardous (classified) location or the ignitable or combustible properties of the specific gas, vapor, dust or fiber that was present:      a) Sawmill  - On or about October 29, 2014, the ceiling lights, junction boxes and other electrical equipment was not marked to indicate that it was safe for use in class II locations.
Recent events (2)
  • · I (S) $1000
  • · Z (S) $1785

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340053362.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.