PARACHUTE, CO ·
OSHA Inspection: CYCLONE DRILLING, INC
Fatality or catastrophe inspection · Safety discipline
At a glance
On , OSHA opened a fatality or catastrophe safety inspection of CYCLONE DRILLING, INC in CYCLONE RIG 17 API 05-045-22491-00, PARACHUTE, CO 81635 (NAICS 213111). OSHA activity number 340053503.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CYCLONE DRILLING, INC
- Site address
- CYCLONE RIG 17 API 05-045-22491-00
- City
- PARACHUTE
- State
- CO
- ZIP
- 81635
- Mailing
- P.O. BOX 908, GILLETTE, WY 82717
What kind of inspection was it?
- Inspection type
- Fatality or catastrophe (M)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 213111
- Employees
- 6
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
5(a)(1)
- Issued
- Apr 17, 2015
- Abate by
- May 22, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to "stuck by" hazards associated with high pressure equipment. (a)Cyclone Rig #17, 05-045-22491-00, Parachute, CO, 81635: On and before October 21st, 2014, the employer did not ensure a threaded two inch pipe nipple used as a means of connection to a fill line valve was adequately secured and could support the pressures involved. As a result of high pressure and inadequate securement (threads of engagement) between the two inch pipe nipple and two inch (Fill Line) valve (Serial #RD12060058), the valve violently separated from the pipe nipple. The two inch pipe nipple was found to have been inadequately tightened into the fill line valve resulting in catastrophic failure of the connection. An employee was fatality injured after being struck by the fill line valve. Abatement Note: Among other methods, one feasible and acceptable means of abatement is to adopt the following "Corrective Actions" listed in the International Association of Drilling Contractors (IADC), Safety Alert document #08-02, titled Standpipe Pressure Gauge Thread Nipple Failure (Under Pressure). 1)Rig supervisors are to ensure crewmembers know how to properly install a high pressure nipple and/or attachments (i.e., gauge, nipple, blow-plug, T-junctions, etc.) 2)When installing or repairing a high pressure line and/or attachments, this task must be supervised by the Rig Manager or Driller to ensure proper nipple selection and installation. 3)Inspect all high pressure lines and fittings to ensure the correct amount of threads have been "buried" (threaded) into the receiving receptacle. Abatement Note: Among other methods, a feasible and acceptable means of abatement would be to ensure all threaded pipe is wrench tight per Table 2 found in the American National Standards Institute/American Society of Mechanical Engineers ANSI/ASME B1.20.1. For two inch pipe, table 2 in this document considers 5 engaged threads to be "hand-tight" with 3 additional threads to be considered "wrench-tight" (total of 8 threads).
Recent events (2)
- · I (S) $7000
- · Z (S) $7000
1910.23 A08 II
- Issued
- Apr 17, 2015
- Abate by
- May 22, 2015
- Penalty
- Initial $2,805 · Current $2,805
General-duty citation text
29 CFR 1910.23(a)(8)(ii): Every floor hole into which persons could accidentally walk were not guarded by a floor hole cover of standard strength and construction: (a)Cyclone Rig #17, 05-045-22491-00, Parachute, CO, 81635: On and before October 21st, 2014, the employer did not ensure floor holes were covered to protect workers from inadvertently walking into the floor hole. The floor hole was located on the discharge side of each (2) Shale Shaker, three sections of floor openings measuring approximately 3-1/2 inches wide by 47 inches long. The condition exposed employees to sprains and lacerations from trip hazards. (b)Cyclone Rig #17, 05-045-22491-00, Parachute, CO, 81635: On and before October 21st, 2014, the employer did not ensure floor holes were covered to protect workers from inadvertently walking into the floor hole. The floor hole was located between Shale Shakers 1 and 2, measuring approximately 7 inches by 5 inches. The condition exposed employees to sprains and lacerations from trip hazards.
Recent events (2)
- · I (O) $2805
- · Z (S) $2805
1910.27 B01 III
- Issued
- Apr 17, 2015
- Abate by
- May 22, 2015
- Penalty
- Initial $3,740 · Current $0 Reduced
General-duty citation text
29 CFR 1910.27(b)(1)(iii): The minimum clear length of rungs or cleats was not 16 inches. (a)Cyclone Rig #17, 05-045-22491-00, Parachute, CO, 81635: On and before October 21st, 2014, the employer did not ensure that the ladder rungs on each "A" leg of the derrick were not less than 16 inches in length. The length of the 1-1/2 inch angle iron used as ladder rungs on each of the derrick "A" legs ranged from zero to approximately eight inches. The condition exposed employees to falls, lacerations, and full body contusions while climbing the two "A" legs ladders.
Recent events (2)
- · I (S) $0
- · Z (S) $3740
1910.27 B01 V
- Issued
- Apr 17, 2015
- Abate by
- May 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.27(b)(1)(v): The rungs of all individual-rung ladders were not designed to prevent the foot from sliding off the ends: (a)Cyclone Rig #17, 05-045-22491-00, Parachute, CO, 81635: On and before October 21st, 2014, the employer did not ensure that the rungs of all individual-rung ladders were designed to prevent the employees foot from sliding off the ends. The ladder consisted of 1-1/2 inch angle iron used as ladder rungs for accessing to the top of each "A" leg. The ladder was not designed and installed to prevent the user from slipping off the ends. The condition exposed employees to cuts, lacerations, and bruises while climbing the two ladders. Abatement Note: Among others, one suggested design may be found in Figure D-1 in 29 CFR 1910.27
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.27 C04
- Issued
- Apr 17, 2015
- Abate by
- May 22, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.27(c)(4): The employer did not install fixed ladders with at least 7 inches of clearance from the centerline of the rung to the nearest permanent object in the back of the ladder. (a)Cyclone Rig #17, 05-045-22491-00, Parachute, CO, 81635: On and before October 21st, 2014, the employer did not ensure the fixed ladder had at least 7 inches of clearance from the centerline of the rung to the nearest permanent object in the back of the ladder. The ladder consisted of 1-1/2 inch angle iron which used as rungs to access the upper portion of each "A" leg. Each piece of angle iron was welded directly to the derrick "A" legs. The condition exposed employees to falls, cuts, lacerations, and bruises, while climbing the two ladders.
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections at Cyclone Drilling, INC
View Cyclone Drilling, INC's full OSHA safety record →
More inspections in this industry (NAICS 213111)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340053503.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.