OSHA Inspection: LINCOLN ELECTRIC COMPANY

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of LINCOLN ELECTRIC COMPANY in 22801 ST. CLAIR AVE., CLEVELAND, OH 44117 (NAICS 333992). OSHA activity number 340055979.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Lincoln Electric Company — free Get an email when a new federal OSHA severe-injury report for Lincoln Electric Company is published. One employer, no account, unsubscribe in one click.
Site address
22801 ST. CLAIR AVE.
City
CLEVELAND
State
OH
ZIP
44117
Mailing
22801 ST. CLAIR AVE., CLEVELAND, OH 44117
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333992
Employees
12000
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 26, 2015
Abate by
Feb 13, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section.    a) On or about September 22, 2014, while cleaning the number three slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  An energy control procedure does exists for maintenance employees but is not utilized by press operators during cleaning operations.    b) On and before October 31, 2014, while cleaning the number one slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  An energy control procedure does exists for maintenance employees but is not utilized by press operators during cleaning operations.    c) On and before October 31, 2014, while cleaning the number two slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  An energy control procedure does exists for maintenance employees but is not utilized by press operators during cleaning operations.    d) On and before October 31, 2014, while cleaning the number four slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  An energy control procedure does exists for maintenance employees but is not utilized by press operators during cleaning operations.
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.147 C07 I A

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 26, 2015
Abate by
Feb 13, 2015
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation.    a) On or about September 22, 2014, while cleaning the number three slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  Slug Press operators are not trained as an authorized user of hazardous energy isolation or required by the employer to utilize hazardous energy control while cleaning the press.    b) On and before October 31, 2014, while cleaning the number one slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  Slug Press operators are not trained as an authorized user of hazardous energy isolation or required by the employer to utilize hazardous energy control while cleaning the press.       c) On and before October 31, 2014, while cleaning the number two slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  Slug Press operators are not trained as an authorized user of hazardous energy isolation or required by the employer to utilize hazardous energy control while cleaning the press.        d) On and before October 31, 2014, while cleaning the number four slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, which exposes them to the point of operation, while the press is still energized.  Slug Press operators are not trained as an authorized user of hazardous energy isolation or required by the employer to utilize hazardous energy control while cleaning the press
Recent events (3)
  • — F (S) $7000
  • — C (S) $7000
  • — Z (S) $7000

1910.147 D03

Serious Gravity 10 4 instances 4 exposed
Issued
Jan 26, 2015
Abate by
Feb 13, 2015
Penalty
Initial $7,000 · Current $0 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy sources.    a) On or about September 22, 2014, while cleaning the number three slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  An energy control procedure does exist for maintenance employees but is not utilized by press operators during cleaning operations which would require them to isolate press from electrical and water pressure energy sources.    b) On and before October 31, 2014, while cleaning the number one slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  An energy control procedure does exist for maintenance employees but is not utilized by press operators during cleaning operations which would require them to isolate press from electrical and water pressure energy sources.    c) On and before October 31, 2014, while cleaning the number two slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  An energy control procedure does exist for maintenance employees but is not utilized by press operators during cleaning operations which would require them to isolate press from electrical and water pressure energy sources.    d) On and before October 31, 2014, while cleaning the number four slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  An energy control procedure does exist for maintenance employees but is not utilized by press operators during cleaning operations which would require them to isolate press from electrical and water pressure energy sources.
Recent events (3)
  • — F (S) $0
  • — C (S) $7000
  • — Z (S) $7000

1910.147 D04 I

Serious Gravity 10 1 instance 4 exposed
Issued
Jan 26, 2015
Abate by
Feb 13, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees.    a) On or about September 22, while cleaning the number three slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized. No lockout or tagout device was affixed to the electrical pull box to isolate the hazardous energy to the press during cleaning operations.     b) On and before October 31, 2014, while cleaning the number one slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized. No lockout or tagout device was affixed to the electrical pull box to isolate the hazardous energy to the press during cleaning operations.     c) On and before October 31, 2014, while cleaning the number two slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized. No lockout or tagout device was affixed to the electrical pull box to isolate the hazardous energy to the press during cleaning operations.     d) On and before October 31, 2014, while cleaning the number four slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized. No lockout or tagout device was affixed to the electrical pull box to isolate the hazardous energy to the press during cleaning operations.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 D05 I

Serious Gravity 10 4 instances 4 exposed
Issued
Jan 26, 2015
Abate by
Feb 13, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(5)(i): All potentially hazardous stored or residual energy was not relieved, disconnected, restrained or otherwise rendered safe after the application of lockout or tagout devices to energy isolating devices.    a) On or about September 22, 2014, while cleaning the number three slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  The hazardous energy control procedure was not utilized and no verification of the dissipation of all hazardous stored energy was done prior to the press cleaning operations being performed.     b) On and before October 31, 2014, while cleaning the number one slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  The hazardous energy control procedure was not utilized and no verification of the dissipation of all hazardous stored energy was done prior to the press cleaning operations being performed.    c) On and before October 31, 2014, while cleaning the number two slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  The hazardous energy control procedure was not utilized and no verification of the dissipation of all hazardous stored energy was done prior to the press cleaning operations being performed.  .  d) On and before October 31, 2014, while cleaning the number four slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted to clean the ram, cylinder, and bin/feed chute, exposing them to the point of operation, while the press is still energized.  The hazardous energy control procedure was not utilized and no verification of the dissipation of all hazardous stored energy was done prior to the press cleaning operations being performed.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 4 instances 4 exposed
Issued
Jan 26, 2015
Abate by
Feb 28, 2015
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) On and before October 31, 2014, while operating the number one slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators hands and fingers were exposed to crushing hazards, form the mechanical door and slug cradle, while rolling slugs to the opposite side of the metal trays as the press is automatically cycling.    b) On and before October 31, 2014, while operating the number two slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators hands and fingers were exposed to crushing hazards, form the mechanical door and slug cradle, while rolling slugs to the opposite side of the metal trays as the press is automatically cycling.    c) On and before October 31, 2014, while operating the number three slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators hands and fingers were exposed to crushing hazards, form the mechanical door and slug cradle, while rolling slugs to the opposite side of the metal trays as the press is automatically cycling.    d) On and before October 31, 2014, while operating the number four slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators hands and fingers were exposed to crushing hazards, form the mechanical door and slug cradle, while rolling slugs to the opposite side of the metal trays as the press is automatically cycling.
Recent events (3)
  • — F (S) $5000
  • — C (S) $5000
  • — Z (S) $5000

1910.212 A03 II

Serious Gravity 5 4 instances 4 exposed
Issued
Jan 26, 2015
Abate by
Feb 28, 2015
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s).    a) On and before October 31, 2014, while operating the number one slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted work directly above the unguarded ram and cylinder, located inside of the bin/feed chute, as it cycled in automatic mode while producing slugs.      b) On and before October 31, 2014, while operating the number two slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted work directly above the unguarded ram and cylinder, located inside of the bin/feed chute, as it cycled in automatic mode while producing slugs.      c) On and before October 31, 2014, while operating the number three slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted work directly above the unguarded ram and cylinder, located inside of the bin/feed chute, as it cycled in automatic mode while producing slugs.      d) On and before October 31, 2014, while operating the number four slug press located in the Consumable division at 22801 St. Clair Ave., Cleveland, Ohio 44117, the press operators were permitted work directly above the unguarded ram and cylinder, located inside of the bin/feed chute, as it cycled in automatic mode while producing slugs.