Safety Incidents OSHA Severe Injury Reports · 2015–2025
3,913,242Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: STICHLER PRODUCTS, INCORPORATED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of STICHLER PRODUCTS, INCORPORATED in 1800 NORTH 12TH STREET, READING, PA 19604 (NAICS 311352). OSHA activity number 340057470.

Watch Stichler Products, Incorporated — free Get an email when a new federal OSHA severe-injury report for Stichler Products, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
1800 NORTH 12TH STREET
City
READING
State
PA
ZIP
19604
Mailing
1800 NORTH 12TH STREET, READING, PA 19604
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311352
Employees
18
Ownership type
A

4 citations on file for this inspection.

1910.303 G01 I A

Serious Gravity 1 2 instances 4 exposed
Issued
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:    (a)  NEAR BACK WAREHOUSE ENTRANCE - The employer did not maintain a minimum of thirty-six (36) inches of clearance in front of the electrical panels next to the back warehouse entry way, thereby exposing employees to possible injury, on or about October 30, 2014.    (b)  UPSTAIRS PRODUCTION ROOM NEAR BREAK AREA - The employer did not maintain a minimum of thirty-six (36) inches of clearance in front of the electrical panels next to the employee break area, thereby exposing employees to possible injury, on or about October 30, 2014.    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.1200 E01

Serious Gravity 1 1 instance 18 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    (a)  FACILITY WIDE - Employees used products including, but not limited to Glass Glo Concentrate, Bowl Bryte, Germicidal Bleach, and Valient Acid Bowl Cleaner, and the employer had not developed and implemented a written hazard communication program, thereby exposing employees to serious injury, on or about October 30, 2014.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.132 D02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated, the person certifying that the evaluation has been performed, the date(s) of the hazard assessment, and, which identifies the document as a certification of hazard assessment:    (a)  FAILITY WIDE - The employer did not verify that the required workplace hazard assessment had been performed through a written certification, on or about October 30, 2014.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):    (a)  FACILITY WIDE - The employer did not certify that the employees who operated forklifts in the facility had been trained and evaluated as required by 29 CFR 1910.178(l).    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340057470.