OSHA Inspection: SEABOARD GRAPHICS SERVICES, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SEABOARD GRAPHICS SERVICES, LLC in 7570 OSWEGO ROAD, LIVERPOOL, NY 13090 (NAICS 323110). OSHA activity number 340057827.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Seaboard Graphics Services, LLC — free Get an email when a new federal OSHA severe-injury report for Seaboard Graphics Services, LLC is published. One employer, no account, unsubscribe in one click.
Site address
7570 OSWEGO ROAD
City
LIVERPOOL
State
NY
ZIP
13090
Mailing
7570 OSWEGO ROAD, LIVERPOOL, NY 13090
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
21
Ownership type
A

7 citations on file for this inspection.

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Feb 12, 2015
Abate by
Feb 23, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.   a) At the Printing Press Area, on or about 10/31/2014: Eye wash was not ready for immediate use for employees working with chemicals such as, but not limited to: Absolute 6036, Supreme RSN 809 Fount, and WASH-V-120.  The installed eyewash lacked the proper pressure to adequately supply the correct amount of water in the event it was needed.
Recent events (3)
  • — J (S) $1600
  • — C (S) $1600
  • — Z (S) $1600

1910.157 E03

Serious Gravity 1 2 instances 4 exposed
Issued
Feb 12, 2015
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a) At the Facility, on or about 10/31/2014: Facility  wide  portable fire extinguishers were not annually inspected. The extinguishers were last inspected on 12/11.
Recent events (3)
  • — J (S) $1200
  • — C (S) $1200
  • — Z (S) $1200

1910.157 G02

Serious Gravity 1 1 instance 4 exposed
Issued
Feb 12, 2015
Abate by
Mar 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:  a) At the Facility, on or about 10/31/2014: Employees were not trained in the use of fire extinguishers when they were expected to fight a fire in the incipient stage.   * Abatement note: By this date the employer must either correct the alleged violation(s) or implement a Fire Safety Policy, as outlined in 29 CFR 1910.38 and 29 CFR 1910.39 which includes the evacuation requirements of 29 CFR 1910.157(b).
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 3 instances 1 exposed
Issued
Feb 12, 2015
Abate by
Mar 20, 2015
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) At the facility, on or about 10/31/2014: Employee operated a Challenge three hole paper drill without guards on the rotating portion of the drill bits, spindles and chucks.
Recent events (3)
  • — J (S) $2800
  • — C (S) $2800
  • — Z (S) $2800

1910.1200 F06

Serious Gravity 5 2 instances 1 exposed
Issued
Feb 12, 2015
Abate by
Mar 20, 2015
Penalty
Initial $1,600 · Current $1,600
29 CFR 1910.1200(f)(6): The employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information specified under paragraphs (f)(6)(i) through (ii) of this section:  a) Printing Press Area, on or about 10/31/2014: Employee used  two 32oz bottles containing WASH-V 120 solvent that were not labeled.                                                              b) Printing Press Area, on or about 10/31/2014: Employee used three one gallon containers that were filled with water,   which  is used to dilute Wash-V 120,  that were not properly labeled with its contents.
Recent events (3)
  • — J (S) $1600
  • — C (S) $1600
  • — Z (S) $1600

1910.1200 H01

Serious Gravity 1 1 instance 3 exposed
Issued
Feb 12, 2015
Abate by
Mar 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a) At the facility, on or about 10/31/2014: Employees had not received training on the Hazard Communication Program.
Recent events (3)
  • — J (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Repeat Gravity 5 1 instance 2 exposed
Issued
Feb 12, 2015
Abate by
Feb 28, 2015
Penalty
Initial $3,200 · Current $3,200
29 CFR 1910.305(g)(1)(iv)(A): 29 CFR 1910.305(g)(1)(iv)A: Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used as a substitute for permanent building wiring.   a) At the facility, On or about 10/31/2014: An extension cord was being used as a substitute for fixed wiring to supply power to the Bessler shrink wrap machine. The cord was permanently affixed to the ceiling from its intial attachment point located on a wall, up the wall , across the ceiling to the machine location.   The Seaboard Graphics Services, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 29CFR1910.305(g)(1)(iv)(A) which was contained in OSHA inspection number314344730, Citation number1, item number 3  citation number and was affirmed as a final order on 7/9/2010, with respect to a workplace located at 7570 Oswego Rd, Liverpool, NY 13090.