OSHA Inspection: DAKOTA BRANDS INTERNATIONAL, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAKOTA BRANDS INTERNATIONAL, INC. in 2121 13TH STREET NE, JAMESTOWN, ND 58401 (NAICS 311812). OSHA activity number 340065507.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Dakota Brands International, INC. — free Get an email when a new federal OSHA severe-injury report for Dakota Brands International, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2121 13TH STREET NE
City
JAMESTOWN
State
ND
ZIP
58401
Mailing
2121 13TH STREET NE, JAMESTOWN, ND 58401
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311812
Employees
33
Ownership type
A

6 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 3 instances 3 exposed
Issued
Apr 21, 2015
Abate by
May 26, 2015
Penalty
Initial $3,500 · Current $1,750 Reduced
Section 5(a)(1): The employer did not furnish a place of employment that was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to potential crushing or struck-by injuries from collapsing storage racks:     (a) On November 4, 2014, and dates prior to, for employees using or working near storage racks with damaged support columns located along the west wall of the storage area immediately west of the truck bay at the facility located at 2121 13th Street NE in Jamestown, North Dakota.     (b) On November 4, 2014, and dates prior to, for employees using or working near a yellow storage rack with a damaged support column that was located in front of a truck bay overhead door in the storage area immediately west of the truck bay at the facility located at 2121 13th Street NE in Jamestown, North Dakota.     (c) On November 4, 2014, and dates prior to, for employees using or working near the storage rack with grey columns and orange horizontal beams, where the horizontal storage beams were modified with a cutting torch, at the facility located at 2121 13th Street NE in Jamestown, North Dakota.     Abatement note: Among other methods, one feasible and acceptable method to correct this hazard is to follow the guidelines described by the Rack Manufacturers Institute in ANSI MH16.2-1984. Specifically, section 3.11 which states that "As soon as damage occurs, the column twisted or distorted, the rack should be unloaded and the rack section removed and replaced with a new upright section" and section 3.2 which states that "The solution to improper beam installation is a periodic inspection of all beam connections, that the initial installation be verified to be consistent with the manufacturers instruction...".
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.253 B04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 21, 2015
Abate by
Apr 28, 2015
Penalty
Initial $3,500 · Current $1,750 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:     (a) On or about November 4, 2014, and dates prior to, for employees exposed to fire and explosion hazards where an oxygen cylinder was stored approximately 10 feet from an acetylene cylinder in the maintenance shop of the facility located at 2121 13th Street NE, in Jamestown, North Dakota.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $3500

1910.305 G01 IV A

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 21, 2015
Abate by
May 4, 2015
Penalty
Initial $2,100 · Current $1,050 Reduced
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords or cables were used as a substitute for the fixed wiring of a structure:     (a) On November 4, 2014, and dates prior to, for employees exposed to electric and fire hazards where the four receptacle outlet, located on the south wall of the compressor room, was wired using a flexible cord at the facility located at 2121 13th Street NE, in Jamestown, North Dakota.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $2100

1910.305 G01 IV B

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 21, 2015
Abate by
May 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:   (a) On November 4, 2014, and dates prior to, for employees exposed to electric and fire hazards where flexible cord powering the dock lights in the truck barn was run through a hole in a concrete wall to an electrical outlet located on the opposite side of the wall at the facility located at 2121 13th Street NE, in Jamestown, North Dakota.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Apr 21, 2015
Abate by
May 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:   (a) On November 4, 2014, and dates prior to, for employees exposed to hazards associated with uncontrolled energy at the facility located at 2121 13th Street NE, in Jamestown, North Dakota.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C07 I A

Other-than-serious 1 instance 2 exposed
Issued
Apr 21, 2015
Abate by
May 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation:   (a) On November 4, 2014, and dates prior to, for employees exposed to hazards associated with uncontrolled energy while utilizing lockout/tagout methods at the facility located at 2121 13th Street NE, in Jamestown, North Dakota.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0