Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: APPLETON SUPPLY CO., INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of APPLETON SUPPLY CO., INC. in 1905 W. HASKEL, APPLETON, WI 54914 (NAICS 332322). OSHA activity number 340066877.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Appleton Supply CO., INC. — free Get an email when a new federal OSHA severe-injury report for Appleton Supply CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
1905 W. HASKEL
City
APPLETON
State
WI
ZIP
54914
Mailing
1905 W. HASKEL, APPLETON, WI 54914
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
68
Ownership type
A

6 citations on file for this inspection.

1910.147 C01

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 19, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training , and periodic inspections, to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative in accordance with 29 CFR 1910.147(c)(4).  (a) On or about June 25, 2014; the employer's energy control procedure did not include periodic inspections to ensure the machine specific procedures were adequate or being followed by all employees.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.147 D

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
Dec 19, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  (a) On or about June 25, 2014; in the Press Department, Press #23 had a jam at the cut off die. The piece of equipment was not properly de-energized prior to entering the hazard zone.  This exposed employee(s) to crushing injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C04 II B

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 19, 2014
Abate by
Feb 11, 2015
Penalty
Initial $4,900 · Current $3,430 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    (a)  The employer failed to develop clear and specific steps for shutting down equipment prior to clearing jams on equipment such as but not limited to:  Press #23.  This exposed employees to accidental/inadvertent restart of the equipment.
Recent events (2)
  • — I (S) $3430
  • — Z (S) $4900

1910.147 C07 I

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 19, 2014
Penalty
Initial $4,900 · Current $0 Reduced
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program was understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls were acquired by employees.      On or about June 25, 2014; the employer did not ensure that the authorized employees were adequately trained in specific LOTO procedures before performing service and maintenance to machine equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.212 A01

Serious Gravity 5 15 instances 15 exposed
Issued
Dec 19, 2014
Abate by
Jan 21, 2015
Penalty
Initial $2,380 · Current $2,380
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:     (a)  In the Press Department, Niagara A 1 3/4 Punch press #23 had inadequate guards by the limit switch used to activate the shear blade exposing employees to crushing and amputation hazards.      (b)  In the Press Department, Niagara A 1 3/4 Punch press #23 by the shear ram had moving parts inadequately guarded exposing employees to crushing hazards.      (c)  In the Press Department, Rousselle Punch Press #8 did not have guards over the moving parts from the ram advancing the sheet into the shear exposing employees to crushing hazards.    (d)  In the Footage Department, the Tru-Cut Tool & Machine Corp Cut Off Die #52 at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop.  (e)  In the Footage Department, the Tru-Cut Tool & Machine Corp Cut Off Die #53 at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop. (f)  In the Footage Department, the Cut Off Die #54 at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop.  (g)  In the Footage Department, Work Center #72 Rafter Machine Co (S/N:  3138) cut off die machine at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop.   (h)  In the Footage Department, Work Center #64 Tru-Tech cut off die machine at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop.  (i)  In the Footage Department, Work Center #50 cut off die machine at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop.   (j)  In the Footage Department, Work Center #57 cut off die machine at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop.   (k)  In the Soffit Department, Work Center #86 cut off die machine at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop.   (l)  In the Soffit Department, Work Center #83 cut off die machine at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop.   (m)  In the Soffit Department, Work Center #75 cut off die machine at the in-feed had inadequate guarding exposing employees to pinch hazards when the die came back and contacted the back stop.  (n)  In the Soffit Department, Knutson #89 cut off die had a gate which could be easily opened allowing access to the blades exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $2380

1910.212 A03 II

Serious Gravity 5 7 instances 15 exposed
Issued
Dec 19, 2014
Abate by
Feb 11, 2015
Penalty
Initial $2,380 · Current $2,380
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):     (a)   In the Press Department, machine #48 had inadequate guarding on the infeed side exposing employees to in-running nip points from the form rollers.     (b)  In the Press Department, the Artos Engineering Co Hemmer Machine #70 had inadequate guarding on the in-feed side in that the guard was could be lifted during operation exposing employees to in-running nip points from the form rollers.     (c)  In the Press Department, machine #42 roll former had inadequate guarding in that the guards could be lifted during operation exposing employees to in-running nip points from the three sets of form rollers.    (d)  In the Press Department, Rouselle Punch Press #8 had the outfeed where the part comes out inadequately guarded in that employees could reach the die blocks exposing employees to struck-by hazards.    (e)  In the Footage Department, the Hemming Machine #52 had inadequate guards in that the guard opening allowed access to the in-running nip points from the form roller.      (f)  In the Footage Department, the Hemming Machine #53 had inadequate guards in that the guard opening allowed access to the in-running nip points from the form roller.     (g)  In the Footage Department, the Hemming Machine #54 had inadequate guards in that the guard opening allowed access to the in-running nip points from the form roller.
Recent events (2)
  • — I (S) $2380
  • — Z (S) $2380

View Appleton Supply CO., INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340066877.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.