WESTPORT, CT —
OSHA Inspection: CABRERA'S FRAMING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CABRERA'S FRAMING LLC in 33 MEEKER STREET, WESTPORT, CT 06880 (NAICS 238130). OSHA activity number 340072578.
Where did this inspection happen?
- Establishment
- CABRERA'S FRAMING LLC
- Site address
- 33 MEEKER STREET
- City
- WESTPORT
- State
- CT
- ZIP
- 06880
- Mailing
- 1010 ELM STREET, STRATFORD, CT 06615
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238130
- Employees
- 4
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): JOBSITE: The employer did not ensure through the completion of a training program and evaluation that the Upright XR840 forklift truck operator was competent to operate the truck safely.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.102 A01
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. JOBSITE: The employee operating a hydraulic nail gun to install trim was not wearing eye protection.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
1926.451 F07
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. JOBSITE: The carpenter's bracket scaffold that an employee worked upon was not erected under the supervision of a competent person in scaffold erection.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.451 G01 VII
- Issued
- Abate by
- Penalty
- Initial $2000.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. JOBSITE: The employee, installing trim from the platform of a carpenter's bracket scaffold was not protected from the hazard of falling 16 feet 6 inches to the ground by the use of guardrails or personal fall arrest system.
Recent events (2)
- — I (S) $1200
- — Z (S) $2000
1926.454 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. JOBSITE: The employee who worked from the platform of a carpenter's bracket scaffold without fall protection was not trained to recognize the hazards associated with the type of scaffold being used.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.602 C01 VI
- Issued
- Abate by
- Penalty
- Initial $1200.00 · Current $600.00 Reduced
General-duty citation text
29 CFR 1926.602(c)(1)(vi): All industrial trucks in use shall meet the applicable requirements of design, construction, stability, inspection, testing, maintenance, and operation, as defined in American National Standards Institute B56.1-1969, Safety Standard for Powered Industrial Trucks: JOBSITE: The Upright XR840 forklift truck, having a cracked windshield and side rearview mirror, was not removed from the service.
Recent events (2)
- — I (S) $600
- — Z (S) $1200
More inspections in this industry (NAICS 238130)
FAIRHOPE, AL—2026-07-16
FRANCISCO ARES
WOODHAVEN, MI—2026-07-16
G.J. PERELLI CO., L.L.C.
PHILADELPHIA, PA—2026-07-16
URUS CONSTRUCTION CORPORATION
BERLIN, NJ—2026-07-16
URUS CONSTRUCTION CORPORATION
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
More inspections in CT
ENFIELD, CT—2026-07-16
MOMS ENFIELD
DAYVILLE, CT—2026-07-16
HARBOR FREIGHT
NEW BRITAIN, CT—2026-07-14
JANANII, LLC
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH BRANFORD, CT—2026-07-14
NYK STATEWIDE MOLINA CONSTRUCTION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340072578.