SHERMAN, MS —
OSHA Inspection: D'S ELECTRIC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of D'S ELECTRIC in 251 WAREHOUSE RD, SHERMAN, MS 38869 (NAICS 811310). OSHA activity number 340073626.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D'S ELECTRIC
- Site address
- 251 WAREHOUSE RD
- City
- SHERMAN
- State
- MS
- ZIP
- 38869
- Mailing
- 124 CR 1355, MOOREVILLE, MS 38857
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811310
- Employees
- 3
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.24 H
- Issued
- Jan 20, 2015
- Abate by
- Jan 30, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.24(h): Standard railings were not provided on the open sides of all exposed stairways and stair platforms: (a) In the maintenance shop - On or about November 6, 2014, the stairs to the overhead storage above the parts storage did not have a mid-rail on the open side.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
1910.253 B04 III
- Issued
- Jan 20, 2015
- Abate by
- Jan 30, 2015
- Penalty
- Initial $1,600 · Current $960 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not seperated from fuel gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire resistant rating of at lest one-half hour; (a) In the maintenance shop - On or about November 6, 2014, 2 oxygen cylinders were stored next to 3 acetylene cylinders under the stairs to the overhead storage and 8 to 10 feet from propane cylinders.
Recent events (2)
- — I (S) $960
- — Z (S) $1600
More inspections at D'S Electric
View D'S Electric's full OSHA safety record →
More inspections in this industry (NAICS 811310)
More inspections in MS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340073626.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.