LOCKPORT, NY —
OSHA Inspection: E & R MACHINE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of E & R MACHINE, INC. in 211 GRAND STREET, LOCKPORT, NY 14094 (NAICS 332710). OSHA activity number 340074533.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- E & R MACHINE, INC.
- Site address
- 211 GRAND STREET
- City
- LOCKPORT
- State
- NY
- ZIP
- 14094
- Mailing
- 211 GRAND STREET, LOCKPORT, NY 14094
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 25
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.37 A03
- Issued
- Nov 18, 2014
- Abate by
- Dec 19, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Stairs or a ramp were not provided where the exit route was not substantially level. a) On or about 11/07/2014 in the warehouse; where the emergency exit on the east wall had a substantial drop (approx. 20 inches) from the door sill height to the ground after passing though the door. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $720
- — Z (S) $1200
1910.147 C06 I C
- Issued
- Nov 18, 2014
- Abate by
- Dec 11, 2014
- Penalty
- Initial $1,500 · Current $900 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i)(C): Where lockout was used for energy control, the periodic inspection did not include a review, between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected: a) On or about 11/07/2014 throughout the production area; where employees engaged in servicing and maintenance operations were not all evaluated while performing an equipment lockout each year. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $900
- — Z (S) $1500
1910.242 B
- Issued
- Nov 18, 2014
- Abate by
- Dec 11, 2014
- Penalty
- Initial $1,200 · Current $720 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 11/07/2014 in the CNC area; where compressed air was used at line pressure (approx. 100 psi) to clean chips out of several CNC machines. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $720
- — Z (S) $1200
More inspections at E & R Machine, INC.
View E & R Machine, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340074533.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.