Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,191,473Inspections Most recent open 2026-07-28 Last loaded 2026-07-31

OSHA Inspection: UNIVERSAL CONTRACTING OF NEW YORK CORP

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of UNIVERSAL CONTRACTING OF NEW YORK CORP in 9013 4TH AVE, BROOKLYN N.Y. 11209, BROOKLYN, NY 11209 (NAICS 238130). OSHA activity number 340076645.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Universal Contracting of NEW York Corp — free Get an email when a new federal OSHA severe-injury report for Universal Contracting of NEW York Corp is published. One employer, no account, unsubscribe in one click.
Site address
9013 4TH AVE, BROOKLYN N.Y. 11209
City
BROOKLYN
State
NY
ZIP
11209
Mailing
111 JOHN ST, SUITE 1010, NEW YORK, N.Y. 10038, NEW YORK, NY 10038
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
6
Ownership type
A

7 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 17, 2015
Abate by
Apr 23, 2015
Penalty
Initial $1,600 · Current $1,020 Reduced
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a program of frequent and regular inspections made by competent persons at the jobsite:      a) Employer did not conduct regular inspection of work that was occurring.  Employees were exposed to fall hazard and electric hazard.      Location: 9013 4th Ave, Brooklyn N.Y. 11209      On or about 11/4/2014       NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1020
  • — Z (S) $1600

1926.451 F15

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 17, 2015
Abate by
Apr 23, 2015
Penalty
Initial $2,000 · Current $1,280 Reduced
29 CFR 1926.451(f)(15):  The employer did not ensure that ladders shall not be used on scaffolds to increase the working level height of employees, except on large area scaffolds where employers have satisfied the criteria listed in (15)(i) through (15)(iv):      a)  A folding A-frame step ladder was placed on top of a scaffold to allow employees to get from the 2fl to the roof. The ladder and scaffold were not secured against movement. Employees were exposed to 10 ft fall hazard.       Location: 9013 4th Ave, Brooklyn N.Y. 11209      On or about 11/4/2014       NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1280
  • — Z (S) $2000

1926.501 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Apr 17, 2015
Penalty
Initial $2,800 · Current $1,840 Reduced
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which is 6 feet (1.8m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems:      a)  Employees were exposed to 25 ft fall hazard when doing construction work at the edge of the 3fl (roof). There were no guardrails and employees were not otherwise protected by fall protection (FP harness tied to lifeline).      Location: 9013 4th Ave, Brooklyn N.Y. 11209      On or about 11/4/2014       NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1840
  • — Z (S) $2800

1926.403 I02 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 17, 2015
Abate by
Apr 23, 2015
Penalty
Initial $2,000 · Current $1,280 Reduced
29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosure:      a)  The wall mounted electric panel box did not have a cover; employees were exposed to electric shock hazard from live electric circuits in the box; in the building near the toolbox.      Location: 9013 4th Ave, Brooklyn N.Y. 11209      On or about 11/4/2014       NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1280
  • — Z (S) $2000

1926.404 B01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 17, 2015
Abate by
Apr 24, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.404(b)(1)(i): The employer did not use either ground fault circuit interrupters (GFCI) or an assured grounding program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites from electric shock hazard when using electric tools and equipment:      a)  Ground fault circuit interrupter (GFCI) were not provided when employees were using electric tools (power saw) at the construction site.      Location: 9013 4th Ave, Brooklyn N.Y. 11209      On or about 11/4/2014       NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 17, 2015
Abate by
Apr 23, 2015
Penalty
Initial $2,000 · Current $1,280 Reduced
29 CFR 1926.1053(b)(1):  When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least three feet above the upper landing surface; or, when such an extension is not possible because of the ladder's length, the ladder was not secured at its top to a rigid support that will not deflect, and a grasping device such as a grab-rail was not provided:      a)  A ladder being used by employees to go from 2fl to 3fl top deck did not extend 3 feet above the deck.  Employees had nothing to hold on to when getting on and off the ladder.        Location: 9013 4th Ave, Brooklyn N.Y. 11209      On or about 11/4/2014       NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
  • — I (S) $1280
  • — Z (S) $2000

1926.1053 B16

Serious Gravity 5 1 instance 1 exposed
Issued
Apr 17, 2015
Abate by
Apr 23, 2015
Penalty
Initial $2,000 · Current $0 Reduced
29 CFR 1926.1053(b)(16): Portable ladders with structural defects were not immediately marked "Defective, Do not Use" and withdrawn from service until repaired:      a)  The employers aluminum extension ladder had damage near the bottom of the side rail, which was repaired by screwing metal to the side rail. The employer did not provide assurance that the repaired side rail remains at least as strong as the original ladder design.        Location: 9013 4th Ave, Brooklyn N.Y. 11209      On or about 11/4/2014       Abatement note: standard 1053(b)(18) requires that ladder repairs shall restore the ladder to a condition meeting its original design criteria, before the ladder is returned to use.      NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM IN ACCORDANCE WITH 29 CFR 1903.19.