OSHA Inspection: KUBIN-NICHOLSON CORPORATION

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of KUBIN-NICHOLSON CORPORATION in 8440 N. 87TH STREET, MILWAUKEE, WI 53224 (NAICS 323110). OSHA activity number 340077338.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Kubin-Nicholson Corporation — free Get an email when a new federal OSHA severe-injury report for Kubin-Nicholson Corporation is published. One employer, no account, unsubscribe in one click.
Site address
8440 N. 87TH STREET
City
MILWAUKEE
State
WI
ZIP
53224
Mailing
8440 N. 87TH STREET, MILWAUKEE, WI 53224
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
50
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Other-than-serious 1 instance 10 exposed
Issued
Apr 14, 2015
Abate by
May 8, 2015
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:    (a) A written Energy Control Program (Lockout/Tagout) was not developed to ensure employee(s) who perform maintenance, repair and setup work on the KBA Rapida 205 Lithographic Press, Folder 1 MBO, Seamer 1 and 2, GA355-100 Air Compressor and other production equipment were not exposed to unexpected energizing, startup or release of stored energy from mechanical equipment.
Recent events (3)
  • — F (O) $0
  • — C (S) $2100
  • — Z (S) $2100

1910.147 C06 I

Serious Gravity 5 1 instance 10 exposed
Issued
Apr 14, 2015
Abate by
Sep 30, 2015
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:     (a) An annual/periodic inspection of the energy control procedures has not been conducted for, but not limited to KBA Rapida 205 Lithographic Press, Folder 1 MBO, Seamer 1 and 2, and GA355-100 Air Compressor to ensure that procedures and requirements of the standard are being followed and that employees who implement energy control procedures understand their application.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1910.147 C07 I A

Serious Gravity 5 1 instance 10 exposed
Issued
Apr 14, 2015
Abate by
Sep 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation and control.     (a) Training was not provided to press operators to ensure that the purpose and function of the energy control program was understood and that the knowledge and skills required for the safe  implementation of energy controls was acquired.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.147 C04 II

Serious Gravity 5 1 instance 10 exposed
Issued
Apr 14, 2015
Abate by
Sep 30, 2015
Penalty
Initial $3,500 · Current $4,000
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to items (a) through (d) of this section:    KBA Rapida 205 Lithographic Printing Press:     (a) The machine specific procedure did not accurately identify press maintenance and repair operations that required lockout tagout to implemented beyond alternative means of protection.
Recent events (3)
  • — F (S) $4000
  • — C (S) $3500
  • — Z (S) $3500

1910.147 D02

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Apr 14, 2015
Abate by
May 1, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  (a) On or about November 12, 2014 employees changed out an ultraviolet lamp module on the KBA Rapida 205 Lithographic printing press without deenergizing the machine and locking out the energy sources. This exposed employees to crushing, caught-in and amputation hazards.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

View Kubin-Nicholson Corporation's full OSHA safety record →