WEST WARWICK, RI ·
OSHA Inspection: J ADAMS MASONRY INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of J ADAMS MASONRY INC. in 854 PROVIDENCE ST., WEST WARWICK, RI 02893 (NAICS 238140). OSHA activity number 340078492.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J ADAMS MASONRY INC.
- Site address
- 854 PROVIDENCE ST.
- City
- WEST WARWICK
- State
- RI
- ZIP
- 02893
- Mailing
- 74 THUNDER TRAIL, CRANSTON, RI 02921
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
1910.134 C01
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use. a. Jobsite: on or about 11/13/2014, the employer did not have a written respiratory protection program established and implemented for required respirator use.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
1926.451 B01 I
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary. a. Jobsite: On or about 11/13/2014, Each platform was not installed so that the space between the adjacent unit and the uprights was no more than 1 inch wide, except where the employer can demonstrate that a wide space is necessary.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.451 C02
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation. a. Jobsite; on or about 11/13/2014, supported scaffold poles did not bear on base plates or other adequate firm foundation.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 E01
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. a. Jobsite; On or about 11/13/2014, scaffold platforms were more than 2 feet above a point of access did not have portable ladders, hook-on-ladders, attachable ladders, stair towers
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 F03
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity. a. Jobsite: On or about 11/13/2014, scaffolding and scaffold components were not inspected for visible defects by a competent person.
Recent events (2)
- · I (S) $1000
- · Z (S) $2000
1926.451 F07
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a. Jobsite; On or about 11/13/2014, the scaffolds were not erected, moved, dismantled, or altered by a competent person.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.454 A
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a. Jobsite; on or about 11/13/2014, the employer did not train employees who performed work while on a scaffold, which would allow employees to understand, control and minimize those hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B01
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $2,800 · Current $1,400 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a. Jobsite; On or about 11/13/2014, each employee on a walking/working surface which was 6 feet or more above a lower level was not protected from falling by the use of a guardrail, safety net, or personal fall arrest system.
Recent events (2)
- · I (S) $1400
- · Z (S) $2800
1926.503 A01
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee who might be exposed to fall hazards. a. Jobsite; on or about 11/13/2014, the employer did not provide training to employees exposed to fall hazards.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.1053 B01
- Issued
- Jan 13, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $1,200 · Current $600 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a. Jobsite; On or about 11/13/2014, The ladder side rails did not extend at least 3 feet above the upper landing surface being accessed.
Recent events (2)
- · I (S) $600
- · Z (S) $1200
More inspections in this industry (NAICS 238140)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340078492.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.