PHILADELPHIA, PA ·
OSHA Inspection: BP CONTRACTORS
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BP CONTRACTORS in 1236 S. HARMONY STREET, PHILADELPHIA, PA 19146 (NAICS 236118). OSHA activity number 340078518.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BP CONTRACTORS
- Site address
- 1236 S. HARMONY STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19146
- Mailing
- 2510 ANNINA LANE, BENSALEM, PA 19020
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 G01 VII
- Issued
- May 8, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) At the jobsite: 1236 Harmony Street - Employees performing bricklaying operations from the 4th level of the fabricated frame scaffold were exposed to fall hazards of approximately thirty-five (35) feet without the use of personal fall arrest systems or guardrail systems. Observed on or about 11/12/2014.
Recent events (1)
- · Z (S) $2800
1926.451 F07
- Issued
- May 8, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) At the jobsite: 1236 Harmony Street - Employees were performing brick operations on a fabricated frame scaffold that was not erected by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection. Observed on or about 11/12/2014.
Recent events (1)
- · Z (S) $0
1926.451 B01
- Issued
- May 8, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(b)(1): Platform(s) on all working levels of scaffolds, were not fully planked or decked between the front uprights and guardrail supports such that the space between adjacent units, and the space between the platform and the uprights is no more than 1 inch wide: a) At the jobsite: 1236 Harmony Street - The working level of a fabricated frame scaffold was not fully planked or decked between the front and rear uprights thus exposing employees to a fall hazard of approximately thirty-five (35) feet. Observed on or about 11/12/2014.
Recent events (1)
- · Z (S) $2800
1926.454 A
- Issued
- May 8, 2015
- Abate by
- May 15, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a) At the jobsite: 1236 Harmony Street - Employees working on a fabricated frame scaffold were not trained by a person qualified to recognize, control, or minimize hazards associated with fabricated frame scaffolding. Observed on or about 11/12/2014.
Recent events (1)
- · Z (S) $0
1926.451 E01
- Issued
- May 8, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) At the jobsite: 1236 Harmony Street - Employees were not provided with a safe means of access and/or egress to a fabricated frame scaffold platform, exposing employees to a fall hazard of approximately thirty-five (35) feet. Employees were using the side frame of the scaffold to access and/or egress the working levels. Observed on or about 11/12/2014.
Recent events (1)
- · Z (S) $1600
1926.451 F06
- Issued
- May 8, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6): a) At the jobsite: 1236 Harmony Street - Employees performing bricklaying operations from a fabricated frame scaffold that was approximately one (1) foot away from a 230 volts service power line were exposed to shock/electrical hazards. The fabricated frame scaffold was erected around the power line. Observed on or about 11/12/2014.
Recent events (1)
- · Z (S) $2800
1926.451 C02
- Issued
- May 8, 2015
- Abate by
- May 14, 2015
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, or uprights did not bear on base plates, mud sills or other adequate firm foundation: a) At the jobsite: 1236 Harmony Street - Employees laying brick were exposed to a collapse hazard as the fabricated frame scaffold did not bear on base plates. Two poles of the scaffold were supported on wood and cinder blocks while the other poles were supported with base plates. Observed on or about 11/12/2014.
Recent events (1)
- · Z (S) $2000
More inspections in this industry (NAICS 236118)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340078518.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.