FLEMINGTON, NJ —
OSHA Inspection: MECHANICAL PRECISION, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MECHANICAL PRECISION, INC. in 11 HOPEWELL AVE., FLEMINGTON, NJ 08822 (NAICS 332710). OSHA activity number 340082478.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MECHANICAL PRECISION, INC.
- Site address
- 11 HOPEWELL AVE.
- City
- FLEMINGTON
- State
- NJ
- ZIP
- 08822
- Mailing
- 11 HOPEWELL AVE., FLEMINGTON, NJ 08822
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 50
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.178 L02 II
- Issued
- Apr 21, 2015
- Abate by
- May 29, 2015
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): Training did not consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operator's performance in the workplace. a) Mechanical Precision Inc., Flemington, NJ - Employees were allowed to drive the forklift without demonstration provided by the trainer and evaluation of the operators performance in the workplace exposing them to struck by hazards. Observed on or about 11/14/2014.
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
1910.303 G01
- Issued
- Apr 21, 2015
- Abate by
- May 15, 2015
- Penalty
- Initial $2,800 · Current $1,820 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not be provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment. a) Mechanical Precision. Inc., Flemington NJ/ Electrical Panel near Exit Door and CNC machines- Electrical panel boxes rated 600 volts or less were blocked by storage materials such as but not limited to a table and wooden pallets. Observed on or 11/14/2014
Recent events (2)
- — I (S) $1820
- — Z (S) $2800
More inspections at Mechanical Precision, INC.
View Mechanical Precision, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332710)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340082478.