OSHA Inspection: BARCO STEEL CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BARCO STEEL CONSTRUCTION, LLC in 1350 GATOR BLVD BEQ BLDG 3601 WING C, JEB LITTLE CREEK, VIRGINIA BEACH, VA 23459 (NAICS 238120). OSHA activity number 340083559.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Barco Steel Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Barco Steel Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1350 GATOR BLVD BEQ BLDG 3601 WING C, JEB LITTLE CREEK
City
VIRGINIA BEACH
State
VA
ZIP
23459
Mailing
10262 SHAWNS GROVE PLACE, MECHANICSVILLE, VA 23116
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
20
Ownership type
A

2 citations on file for this inspection.

1926.351 A02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 25, 2014
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1926.351(a)(2): Current carrying parts of manual electrode holder(s) passing through the gripping portion or the outer surfaces of the jaws were not fully insulated against the maximum voltage encountered to ground:  a)    BEQ Bldg. 3601 Renovation Project, Wing "C", Ground Level, Joint Expeditionary Base Little Creek, VA:  On or about 11/14/14, the insulators surrounding the outer surface of the grip handles of two electrode holders were missing insulation, thus exposing employee(s) to an electrical shock hazard.      No abatement certification or documentation is required.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600

1926.351 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 25, 2014
Penalty
Initial $1,600 · Current $1,200 Reduced
29 CFR 1926.351(b)(2): Welding cable(s) in use were not free from improper repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder was connected:  a)    BEQ Bldg. 3601 Renovation Project, Wing "C", Ground Level, Joint Expeditionary Base Little Creek Virginia Beach, VA:  On or about 11/14/14, employees of Barco Steel Construction were performing operations with a welding cable that contained cuts in the insulation.  The cuts in the welding cable were observed approximately 31 and 61 inches from the electrode holder.  Both cuts in the insulations were wrapped with electrical tape to cover the exposed internal conductor wires, thus exposing employee(s) to possible burn and electrical shock hazards    No abatement certification or documentation required.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1600