Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ELLITE GROUP LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ELLITE GROUP LLC in 108 BOULEVARD, HASBROUCK HEIGHTS, NJ 07604 (NAICS 238140). OSHA activity number 340087295.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ellite Group LLC — free Get an email when a new federal OSHA severe-injury report for Ellite Group LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ELLITE GROUP LLC
Site address
108 BOULEVARD
City
HASBROUCK HEIGHTS
State
NJ
ZIP
07604
Mailing
79 SOUTH MAIN STREET, LODI, NJ 07644
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.451 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 30, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  a- Exterior Pump Jack Scaffold: Pump Jack poles were not secured on a firm foundation exposing workers to scaffold collapse hazards. On or about 11/13/14
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 E01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 30, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.    a-Exterior Pump Jack Scaffold: An employee engaged in masonry from a pump jack scaffold work platform was exposed to fall hazards of approximately 12ft to the concrete below as a means of scaffold access was not present.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 F06

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 30, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they or any conductive material handled on them might come closer than 10 ft to exposed and energized power lines.  a-Exterior Pump Jack Scaffold: CSHO observed that masonry stone work had been completed within approximately one foot to an energized secondary power line which had not been de-energized. On or about 11/08/2014
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 30, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection.  a-Exterior Pump Jack Scaffold: An employee engaged in masonry stone-work was exposed to fall hazards of approximately 12ft to the concrete below as a means of fall protection was not utilized. On or about 11/13/2014
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1926.452 J02

Serious Gravity 10 1 instance 1 exposed
Issued
Dec 30, 2014
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.  a-Exterior Pump Jack Scaffold; An employee was exposed to pole scaffold collapse as triangular bracing was not installed at the pump jack scaffold base.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

View Ellite Group LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340087295.