Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,196,249Inspections Most recent open 2026-08-20 Last loaded 2026-08-24

OSHA Inspection: PROBUILD COMPANY, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PROBUILD COMPANY, LLC in 516 6TH AVE. EAST, BRADENTON, FL 34208 (NAICS 423310). OSHA activity number 340088244.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Probuild Company, LLC for free Get an email when a new federal OSHA severe-injury report for Probuild Company, LLC is published. One employer, no account, unsubscribe in one click.
Site address
516 6TH AVE. EAST
City
BRADENTON
State
FL
ZIP
34208
Mailing
516 6TH AVE. EAST, BRADENTON, FL 34208
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423310
Employees
46
Ownership type
Private (A)

4 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Dec 12, 2014
Penalty
Initial $2,380 · Current $1,428 Reduced
29 CFR 1910.37(a)(3):  Exit route(s) were not kept free and unobstructed:  (a). In Warehouse #2 the exit route was blocked by a large portable fan, on or about December 9, 2014.
Recent events (2)
  • · I (S) $1428
  • · Z (S) $2380

1910.37 B01

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 12, 2014
Penalty
Initial $1,785 · Current $1,071 Reduced
29 CFR 1910.37(b)(1):  The exit route was not adequately lit so that an employee with normal vision could see along the exit route.  (a). In Warehouse #2 the exit at the rear of the building was not provided with adequate lighting to make it obvious and visible to employees working in the area, on or about December 9, 2014.
Recent events (2)
  • · I (S) $1071
  • · Z (S) $1785

1910.37 B04

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(4):  When the direction of travel to the exit or exit discharge was not immediately apparent, signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge:  (a). In Warehouse #2 signage was not provided to direct employees to the exit door located at the rear of the building, on or about December 9, 2014.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 C01

Other-than-serious 1 instance 1 exposed
Issued
Dec 12, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):  Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:  (a). In Warehouse #2 the location of portable fire extinguishers was not identified, on or about December 9, 2014.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View Probuild Company, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340088244.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.