NEW HAVEN, CT —
OSHA Inspection: SPARTAN INDUSTRIES LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of SPARTAN INDUSTRIES LLC in 390 FOXON BLVD, NEW HAVEN, CT 06513 (NAICS 236220). OSHA activity number 340089812.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SPARTAN INDUSTRIES LLC
- Site address
- 390 FOXON BLVD
- City
- NEW HAVEN
- State
- CT
- ZIP
- 06513
- Mailing
- 58 SUMMER LANE, NORTH HAVEN, CT 06473
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236220
- Employees
- 3
- Ownership type
- A
Citations
9 citations on file for this inspection.
1926.102 A01
- Issued
- Feb 18, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.102(a)(1): Employees shall be provided with eye and face protection equipment when machines or operations present potential eye or face injury from physical, chemical, or radiation agents. WORKSITE: The employees operating the following equipment were not wearing any eye protection: 1. The pneumatic nailing device. 2. The DeWalt model DW705 Compound Miter Saw.
Recent events (1)
- — Z (S) $0
1926.304 G01
- Issued
- Feb 18, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.304(g)(1): Radial Saws: The upper hood shall completely enclose the upper portion of the blade down to a point that will include the end of the saw arbor. The upper hood shall be constructed in such a manner and of such material that it will protect the operator from flying splinters, broken saw teeth, etc., and will defect sawdust away from the operator. The sides of the lower exposed portion of the blade shall be guarded to the full diameter of the blade by a device that will automatically adjust itself to the thickness of the stock and remain in contact with stock being cut to give maximum protection possible for the operation being performed. WORKSITE: The guard for the sides of the lower blade of the DeWalt model DW705 compound miter saw, serial number 139244, was secured in the open position, exposing the lower portion of the blade.
Recent events (1)
- — Z (S) $0
1926.404 F06
- Issued
- Feb 18, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.404(f)(6): Grounding path. The path to ground from circuits, equipment, and enclosures shall be permanent and continuous: WORKSITE: The attachment plug of the orange 50-foot extension cord, used to energize the DeWalt model DW705 compound miter saw was missing the ground pin.
Recent events (1)
- — Z (S) $0
1926.405 B02
- Issued
- Feb 18, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(b)(2): Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. WORKSITE: The electrical box having duplex outlets, used to energize the DeWalt model DW705 compound miter saw and a battery charging unit was missing the cover, exposing the live wiring.
Recent events (1)
- — Z (S) $0
1926.405 G01 III C
- Issued
- Feb 18, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(1)(iii)(C): Prohibited uses. Unless necessary for a use permitted in paragraph (g)(1)(i) of this section, flexible cords and cables shall not be used where run through doorways, windows, or similar openings, except as permitted in paragraph (a)(2)(ii)(1) of this section. WORKSITE: Three (3) orange extension cords, used to energize equipment on the worksite went through the front door, and a metal door was resting on the cords.
Recent events (1)
- — Z (S) $0
1926.451 B05 I
- Issued
- Feb 18, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(5)(i): Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end. WORKSITE: The cantilevered portion of the scaffold planks used on the following scaffolds extended more than 12 inches, and the planks were not adequately installed and/or secured in place to prevent from tipping: 1. The step ladder scaffold, the left end extended 64 inches. 2. The step ladder scaffold, the right end extended 37 inches. 3. The job-made supported scaffold, the right end extended 18 inches. 4. The scaffold plank between the job-made supported scaffold and the fabricated frame scaffold, the left end extended 24 inches. 5. The scaffold plank between the fabricated frame scaffold and another job-made supported scaffold, the right end extended more than 30 inches.
Recent events (1)
- — Z (S) $0
1926.451 F15
- Issued
- Feb 18, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(15): Ladders shall not be used on scaffolds to increase the working level height of employees, except on large area scaffolds where employers have satisfied the following criteria: WORKSITE: A 5-foot fiberglass stepladder was placed on the scaffold for the employees to have access the roof from the scaffold, and it was resting against the wall.
Recent events (1)
- — Z (S) $0
1926.452 N01
- Issued
- Feb 18, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(n)(1): Scaffold platforms shall not be placed any higher than the second highest rung or step of the ladder supporting the platform. WORKSITE: The plank, used on the stepladder scaffold was placed on the highest rung of the ladder.
Recent events (1)
- — Z (S) $0
1926.501 B01
- Issued
- Feb 18, 2015
- Abate by
- Feb 26, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(1): "Unprotected sides and edges." Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level shall be protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. WORKSITE: The employee, working on the 8 in 12 pitch roof as well as the top plate of the parapet wall were not protected from the hazards of fall between 10 feet 7 inches and 17 feet by the use of appropriate fall protection systems and or devices.
Recent events (1)
- — Z (S) $0
More inspections at Spartan Industries LLC
View Spartan Industries LLC's full OSHA safety record →
More inspections in this industry (NAICS 236220)
More inspections in CT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340089812.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.