PARAMUS, NJ ·
OSHA Inspection: ANTHONY & SON PLUMBING & HEATING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ANTHONY & SON PLUMBING & HEATING in 250 VIVIEN CT., PARAMUS, NJ 07652 (NAICS 238220). OSHA activity number 340090802.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ANTHONY & SON PLUMBING & HEATING
- Site address
- 250 VIVIEN CT.
- City
- PARAMUS
- State
- NJ
- ZIP
- 07652
- Mailing
- 17 MANING RD, PARAMUS, NJ 07652
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238220
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.1051 A
- Issued
- Dec 17, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided: a) Access from garage level to first floor: Employees were accessing the first floor from the garage level by climbing a 39" concrete/frame opening, being exposed to a fall, on or about 11/5/14.
Recent events (2)
- · I (S) $800
- · Z (S) $1600
1926.1052 C01
- Issued
- Dec 17, 2014
- Penalty
- Initial $1,600 · Current $800 Reduced
General-duty citation text
29 CFR 1926.1052(c)(1): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail and one stairrail system along each unprotected side or edge: a) Main interior stairway to second floor: Employees were using an interior stairway that did not have a handrail to access the second floor of a residence, being exposed to a fall, on or about 11/5/14.
Recent events (2)