SANFORD, FL —
OSHA Inspection: HARPER LIMBACH, LLC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of HARPER LIMBACH, LLC. in 5401 BENCHMARK LN., SANFORD, FL 32773 (NAICS 237110). OSHA activity number 340091495.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HARPER LIMBACH, LLC.
- Site address
- 5401 BENCHMARK LN.
- City
- SANFORD
- State
- FL
- ZIP
- 32773
- Mailing
- 5401 BENCHMARK LN., SANFORD, FL 32773
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 140
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.253 B04 III
- Issued
- Dec 10, 2014
- Abate by
- Dec 17, 2014
- Penalty
- Initial $3,000 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. a) On or above 11/18/2014 in the tool shop, the welding cylinders (oxygen and acetylene) with the regulators and gauges on were not stored separately, exposing employees to a fire hazard.
Recent events (2)
- — I (O) $1800
- — Z (S) $3000
1910.242 B
- Issued
- Dec 10, 2014
- Abate by
- Dec 17, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 11/18/2014 throughout the tool shop area, blow guns on compressed air hoses had pressures of more than 30 PSI, exposing employees to struck-by hazard.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Harper Limbach, LLC.