OSHA Inspection: SCHROEDER SEPTIC SYSTEMS

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SCHROEDER SEPTIC SYSTEMS in 6808 CO RD B, PULASKI, WI 54162 (NAICS 238910). OSHA activity number 340093707.

Watch Schroeder Septic Systems — free Get an email when a new federal OSHA severe-injury report for Schroeder Septic Systems is published. One employer, no account, unsubscribe in one click.
Site address
6808 CO RD B
City
PULASKI
State
WI
ZIP
54162
Mailing
W111 ALBERS ROAD, DE PERE, WI 54115
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
2
Ownership type
A

4 citations on file for this inspection.

1926.21 B02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury:  a)  The employer did not instruct his employees in excavation safety such as cave-in hazards and cave-in protection prior to working in an approximately 7.5 ft. D excavation.
Recent events (1)
  • — Z (S) $0

1926.651 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.  a)  On or about 11-18-14, employer failed to keep excavated material more than two (2) feet from the excavation wall on the east side of the excavation.
Recent events (1)
  • — Z (S) $0

1926.651 K01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:  a)  Employer did not conduct adequate safety inspections prior to employees working in an approximately 14.5 ft. L x 10.5 ft. w x 7.5 ft. D excavation.  Complete soil testing and classification was not conducted, spoil piles were not set-back at least two (2) feet from the wall, and required cave-in protection was not utilized.
Recent events (1)
  • — Z (S) $0

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(b) or 1926.652(c):  a)  On 11-18-14, employees were working in an approximately 14.5 ft. L x 10.5 ft. W x 7.5 ft. D excavation without adequate cave-in protection.  The employer had constructed excavation walls at an approximate 45 deg. angle and not the required 34 deg. angle based on Type C soil.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340093707.