Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AMTEX PRECISION FABRICATION, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of AMTEX PRECISION FABRICATION, INC. in 3920 BAHLER AVENUE, MANVEL, TX 77578 (NAICS 332999). OSHA activity number 340094036.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Amtex Precision Fabrication, INC. — free Get an email when a new federal OSHA severe-injury report for Amtex Precision Fabrication, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3920 BAHLER AVENUE
City
MANVEL
State
TX
ZIP
77578
Mailing
3920 BAHLER AVENUE, MANVEL, TX 77578
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
23
Ownership type
A

8 citations on file for this inspection.

1910.95 C01

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1910.95(c)(1): The employer did not administer a continuing, effective hearing conservation program, as described in paragraphs (c) through (o) of this section, whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level (TWA) of 85 decibels measured on the A scale (slow response) or, equivalently, a dose of fifty percent.       At the sander department; the employer did not develop and implement a hearing conservation program for employees who were exposed to continuous noise exposures that exceeded an 8-hour time-weighted average of 85 decibels or an equivalent dose of one hundred percent.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $3080

1910.95 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.95(g)(1): The employer did not establish and maintain an audiometric testing program as provided in this paragraph by making audiometric testing available to all employees whose exposures equal or exceed an 8-hour time-weighted average of 85 decibels.      At the facility, the employer did not conduct or maintain an audiometric testing program when employees were exposed to continuous noise exposures equaled or exceeded an 8-hour time-weighted average of 85 decibels.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.95 G05 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.95(g)(5)(i): Within 6 months of an employee's first exposure at or above the action level, the employer did not establish a valid baseline audiogram against which subsequent audiograms can be compared.      At the facility, the employer did not establish or conduct a baseline for employees who were exposed to continuous noise exposures equaled or exceeded an 8-hour time-weighted average of 85 decibels.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.141 G02

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $1,870 · Current $940 Reduced
29 CFR 1910.141(g)(2): Eating and drinking areas. An employee was allowed to consume food or beverages in a toilet room nor in any area exposed to a toxic material.         At the welding department; an employee consumed food in a toxic work area, exposing employees to ingestion hazards.
Recent events (2)
  • — I (S) $940
  • — Z (S) $1870

1910.252 C01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.252(c)(1)(ii): Screens. When welding must be performed in a space entirely screened on all sides, the screens were not arranged that no serious restriction of ventilation exists. It is desirable to have the screens so mounted that they are about 2 feet (0.61 m) above the floor unless the work is performed at so low a level that the screen must be extended nearer to the floor to protect nearby workers from the glare of welding.      At welding department; employees welded on stainless steel without adequate welding screens, exposing employees eye injuries.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $3,080 · Current $1,540 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders shall be stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons.          Adjacent to welding department; compressed gas cylinders were not secured to prevent movement, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $1540
  • — Z (S) $3080

1910.253 B04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(i): Oxygen cylinders were stored near highly combustible material, acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment.       Adjacent to welding department; oxygen gas cylinders were stored next to acetylene gas cylinders, exposing employees to fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $2,244 · Current $1,122 Reduced
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinder is designed to accept a cap, shall always be in place, hand-tight, except when cylinders are in use or connected for use.        Adjacent to welding department; compressed gas cylinders were stored without valve protection caps, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $1122
  • — Z (S) $2244

View Amtex Precision Fabrication, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340094036.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.