Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROCKY MOUNTAIN ENVIRONMENTAL INC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of ROCKY MOUNTAIN ENVIRONMENTAL INC in 325 HIGHWAY 8, MORRISON, CO 80465 (NAICS 562910). OSHA activity number 340094556.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rocky Mountain Environmental INC — free Get an email when a new federal OSHA severe-injury report for Rocky Mountain Environmental INC is published. One employer, no account, unsubscribe in one click.
Site address
325 HIGHWAY 8
City
MORRISON
State
CO
ZIP
80465
Mailing
5822 E. 127TH LANE, THORNTON, CO 80602
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.1101 F02 I

Other-than-serious 1 instance 4 exposed
Issued
Dec 3, 2014
Abate by
Dec 9, 2014
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.1101(f)(2)(i):  The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation:          a)   On or about October 24, 2014, and at times prior, Rocky Mountain Environmental, Inc., as a controlling employer, did not ensure that Sub At Best, LLC (subcontractor) protected their employees from airborne asbestos fibers while removing asbestos containing material (including surfacing material on drywall) in the absence of an initial exposure assessment.
Recent events (2)
  • — I (O) $1020
  • — Z (S) $1020

1926.1101 H03 IV A

Other-than-serious 1 instance 4 exposed
Issued
Dec 3, 2014
Abate by
Dec 9, 2014
Penalty
Initial $0 · Current $0
29 CFR 1926.1101(h)(3)(iv)(A):  A tight-fitting powered air-purifying respirator or a full facepiece, supplied-air respirator operated in the pressure-demand mode and equipped with either HEPA egress cartridges or an auxiliary positive-pressure, self-contained breathing apparatus (SCBA) was not provided to employees in a regulated area performing Class I asbestos work for which a negative exposure assessment was not available and the exposure assessment indicated that the exposure level will be at or below 1 f/cc as an 8-hour time-weighted average (TWA):    a)  On or about October 24, 2014, and at times prior, Rocky Mountain Environmental, Inc., as a controlling employer, did not ensure that Sub At Best, LLC (subcontractor) provided employees performing Class I asbestos abatement work with a full-face powered air-purifying respirator or a supplied air respirator to protect them from asbestos fibers.  Employees were performing removal of asbestos containing dry wall texturing with only full and half face air purifying respirators.  A negative exposure assessment had not been conducted for this project.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.1101 G05 I B 2

Other-than-serious 1 instance 4 exposed
Issued
Dec 3, 2014
Abate by
Dec 9, 2014
Penalty
Initial $1,020 · Current $1,020
29 CFR 1926.1101(g)(5)(i)[B][2]:  Electrical circuits in the enclosure shall be deactivated, unless equipped with ground-fault circuit interrupters:      a)  On or about October 24, 2014, and at times prior, Rocky Mountain Environmental, Inc., as a controlling employer, did not ensure that Sub At Best, LLC (subcontractor) protected their employees from electrical shock hazards while they worked inside an asbestos abatement enclosure in which all electrical circuits had not been deactivated or equipped with a ground-fault interrupter.  The wiring of the house (inside the walls) was not protected with ground-fault circuit interrupters.
Recent events (2)
  • — I (O) $1020
  • — Z (S) $1020

View Rocky Mountain Environmental INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340094556.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.