MORRISON, CO —
OSHA Inspection: ROCKY MOUNTAIN ENVIRONMENTAL INC
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ROCKY MOUNTAIN ENVIRONMENTAL INC in 325 HIGHWAY 8, MORRISON, CO 80465 (NAICS 562910). OSHA activity number 340094556.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ROCKY MOUNTAIN ENVIRONMENTAL INC
- Site address
- 325 HIGHWAY 8
- City
- MORRISON
- State
- CO
- ZIP
- 80465
- Mailing
- 5822 E. 127TH LANE, THORNTON, CO 80602
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 562910
- Employees
- 4
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.1101 F02 I
- Issued
- Dec 3, 2014
- Abate by
- Dec 9, 2014
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.1101(f)(2)(i): The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation: a) On or about October 24, 2014, and at times prior, Rocky Mountain Environmental, Inc., as a controlling employer, did not ensure that Sub At Best, LLC (subcontractor) protected their employees from airborne asbestos fibers while removing asbestos containing material (including surfacing material on drywall) in the absence of an initial exposure assessment.
Recent events (2)
- — I (O) $1020
- — Z (S) $1020
1926.1101 H03 IV A
- Issued
- Dec 3, 2014
- Abate by
- Dec 9, 2014
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1101(h)(3)(iv)(A): A tight-fitting powered air-purifying respirator or a full facepiece, supplied-air respirator operated in the pressure-demand mode and equipped with either HEPA egress cartridges or an auxiliary positive-pressure, self-contained breathing apparatus (SCBA) was not provided to employees in a regulated area performing Class I asbestos work for which a negative exposure assessment was not available and the exposure assessment indicated that the exposure level will be at or below 1 f/cc as an 8-hour time-weighted average (TWA): a) On or about October 24, 2014, and at times prior, Rocky Mountain Environmental, Inc., as a controlling employer, did not ensure that Sub At Best, LLC (subcontractor) provided employees performing Class I asbestos abatement work with a full-face powered air-purifying respirator or a supplied air respirator to protect them from asbestos fibers. Employees were performing removal of asbestos containing dry wall texturing with only full and half face air purifying respirators. A negative exposure assessment had not been conducted for this project.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1926.1101 G05 I B 2
- Issued
- Dec 3, 2014
- Abate by
- Dec 9, 2014
- Penalty
- Initial $1,020 · Current $1,020
General-duty citation text
29 CFR 1926.1101(g)(5)(i)[B][2]: Electrical circuits in the enclosure shall be deactivated, unless equipped with ground-fault circuit interrupters: a) On or about October 24, 2014, and at times prior, Rocky Mountain Environmental, Inc., as a controlling employer, did not ensure that Sub At Best, LLC (subcontractor) protected their employees from electrical shock hazards while they worked inside an asbestos abatement enclosure in which all electrical circuits had not been deactivated or equipped with a ground-fault interrupter. The wiring of the house (inside the walls) was not protected with ground-fault circuit interrupters.
Recent events (2)
- — I (O) $1020
- — Z (S) $1020
More inspections at Rocky Mountain Environmental INC
View Rocky Mountain Environmental INC's full OSHA safety record →