2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: SUB AT BEST, LLC

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of SUB AT BEST, LLC in 325 HIGHWAY 8, MORRISON, CO 80465 (NAICS 562910). OSHA activity number 340094630.

Watch SUB AT Best, LLC — free Get an email when a new federal OSHA severe-injury report for SUB AT Best, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SUB AT BEST, LLC
Site address
325 HIGHWAY 8
City
MORRISON
State
CO
ZIP
80465
Mailing
1200 S. ONEIDA STREET APT 12-107, DENVER, CO 80224
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
562910
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.1101 F02 I

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $600.00 Reduced
29 CFR 1926.1101(f)(2)(i):  The employer with a work operation covered by the asbestos standard did not ensure that a "competent person" conducted an exposure assessment immediately before or at the initiation of the operation to ascertain expected exposures during that operation:          a)   On or about October 24, 2014, and at times prior, employees were exposed to unknown quantities of airborne asbestos fibers while removing asbestos containing material (including surfacing material on drywall) because the employer had failed to perform an initial exposure assessment.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1020

1926.1101 H03 IV A

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1101(h)(3)(iv)(A):  A tight-fitting powered air-purifying respirator or a full facepiece, supplied-air respirator operated in the pressure-demand mode and equipped with either HEPA egress cartridges or an auxiliary positive-pressure, self-contained breathing apparatus (SCBA) was not provided to employees in a regulated area performing Class I asbestos work for which a negative exposure assessment was not available and the exposure assessment indicated that the exposure level will be at or below 1 f/cc as an 8-hour time-weighted average (TWA):  a)  On or about October 24, 2014, and at times prior, the employer did not provide employees performing Class I asbestos abatement work with a full-face powered air-purifying respirator or a supplied air respirator.  Employees were performing removal of asbestos containing dry wall texturing with only full and half face air purifying respirators.  A negative exposure assessment had not been conducted for this project.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1101 G05 I B 2

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $600.00 Reduced
29 CFR 1926.1101(g)(5)(i)[B][2]:  Electrical circuits in the enclosure shall be deactivated, unless equipped with ground-fault circuit interrupters:      a)  On or about October 24, 2014, and at times prior, employees were exposed to electrical shock hazards while they worked inside an asbestos abatement enclosure in which all electrical circuits had not been deactivated or equipped with a ground-fault interrupter.  The wiring of the house (inside the walls) was not protected with ground-fault circuit interrupters.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1020