OSHA Inspection: SUPERIOR CRANE CORP.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SUPERIOR CRANE CORP. in 208 WILMONT DRIVE, WAUKESHA, WI 53189 (NAICS 423830). OSHA activity number 340097377.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Superior Crane Corp. — free Get an email when a new federal OSHA severe-injury report for Superior Crane Corp. is published. One employer, no account, unsubscribe in one click.
Site address
208 WILMONT DRIVE
City
WAUKESHA
State
WI
ZIP
53189
Mailing
PO BOX 1464, WAUKESHA, WI 53189
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423830
Employees
85
Ownership type
A

10 citations on file for this inspection.

1910.106 D02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 4, 2015
Penalty
Initial $2,100 · Current $1,680 Reduced
29 CFR 1910.106(d)(2)(i): Approved containers and/or portable tanks were not used for the storage of flammable liquids:     (a)     The painter's cart held 3 metal coffee cans with plastic covers which contained lacquer thinner.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2100

1910.106 E09 III

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
May 4, 2015
Penalty
Initial $2,100 · Current $1,680 Reduced
29 CFR 1910.106(e)(9)(iii): Combustible waste material and residues in a building or unit operating area were not kept to a minimum, stored in covered metal receptacles and disposed of daily:    (a)     In the outside flammable liquid storage room the general combustible waste was collected in a fiberboard waste container and was emptied twice a week.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2100

1910.107 G03

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
May 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.107(g)(3):  The contents of waste cans were not properly disposed of at least once daily or at the end of each shift.  (a)     In the outside flammable liquid storage room the contents of the metal oily rag waste can was emptied once a week.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.107 G02

Serious Gravity 5 1 instance 50 exposed
Issued
Apr 22, 2015
Abate by
May 4, 2015
Penalty
Initial $3,500 · Current $2,800 Reduced
29 CFR 1910.107(g)(2): All spraying areas were not kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary:    (a)     The floor in the West bay and the floor in the North bay had an accumulation of paint overspray that was not removed.
Recent events (2)
  • — I (S) $2800
  • — Z (S) $3500

1910.134 C02 II

Serious Gravity 5 1 instance 50 exposed
Issued
Apr 22, 2015
Abate by
Jun 10, 2015
Penalty
Initial $4,200 · Current $3,360 Reduced
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user:    (a)     The welder used a negative pressure half-face piece respirator and a medical determination had not been obtained.
Recent events (2)
  • — I (S) $3360
  • — Z (S) $4200

1910.134 D03 III B 2

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
May 4, 2015
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.134(d)(3)(iii)(B)(2): The employer did not implement a change schedule for respirators not equipped with an End of Service Life Indicator that would ensure cartridges were changed before the end of their service life:     (a)     Painters wearing respirators with organic vapor cartridges and paint mist pre-filters were not following any cartridge change schedule.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.134 F02

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 4, 2015
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested:    (a)     Employees such as painters were not given annual respirator fit tests.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.134 G01 I B

Serious Gravity 1 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 4, 2015
Penalty
Initial $2,100 · Current $0 Reduced
29 CFR 1910.134(g)(1)(i)(B): Respirators with tight-fitting facepieces were worn by employees with a condition that interfered with the face-to-facepiece seal or valve function:    (a)     Painters wore the spray sock on their heads which came between the sealing surface of the respirator facepiece and the face.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2100

1910.303 B02

Other-than-serious 1 instance 1 exposed
Issued
Apr 22, 2015
Abate by
May 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  (a)     The non-metallic sheathed cable used to wire the cardboard box compactor in the west bay was not protected from physical damage and was not supported within 12 inches of each electrical cabinet.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 B02 I

Other-than-serious 1 instance 1 exposed
Issued
Apr 22, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:  (a)     In the north bay the junction box mounted on the south wall was missing a cover.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Superior Crane Corp.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340097377.