OSHA Inspection: DAVIS BROS. INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DAVIS BROS. INC. in 4521 COUNTY ROUTE 4, OSWEGO, NY 13126 (NAICS 424410). OSHA activity number 340100189.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Davis Bros. INC. — free Get an email when a new federal OSHA severe-injury report for Davis Bros. INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DAVIS BROS. INC.
Site address
4521 COUNTY ROUTE 4
City
OSWEGO
State
NY
ZIP
13126
Mailing
4521 COUNTY ROUTE 4, OSWEGO, NY 13126
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424410
Employees
18
Ownership type
A

8 citations on file for this inspection.

1910.23 A10

Serious Gravity 5 1 instance 11 exposed
Issued
Dec 17, 2014
Abate by
Jan 21, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.23(a)(10): A platform was not provided where door(s) or gate(s) opened directly on a stairway:    a)  Dry Storage Warehouse, on or about 11/24/14:  Exit door opened directly on a stairway.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.36 D01

Serious Gravity 5 2 instances 10 exposed
Issued
Dec 17, 2014
Abate by
Dec 27, 2014
Penalty
Initial $0 · Current $0
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge:  a)  Dry Storage Warehouse, on or about 11/24/14:  Emergency exit door was locked with a slide bolt.  b)  Basement, on or about 11/24/14:  Overhead door marked as an exit was locked with a slide bolt.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B01

Serious Gravity 5 1 instance 11 exposed
Issued
Dec 17, 2014
Abate by
Jan 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that an employee with normal vision could see along the exit route:  a)  Davis Bros. Inc., on or about 11/24/14:  Emergency lighting was not provided in the facility to adequately light each exit route.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.37 B06

Serious Gravity 5 4 instances 11 exposed
Issued
Dec 17, 2014
Abate by
Jan 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(6): Each exit sign was not illuminated to a surface value of at least five foot-candles (54 lux) by a reliable light source and be distinctive in color:  a)  Throughout the facility, on or about 11/24/14:  Exits signs were not illuminated.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.36 B01

Serious Gravity 5 1 instance 11 exposed
Issued
Dec 17, 2014
Abate by
Jan 21, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.36(b)(1): At least two exits routes were not available to permit prompt evacuation of employees during an emergency.       a)  Basement, on or about 11/24/14:  Two exit routes were not available for prompt evacuation of employees during an emergency.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.157 G01

Serious Gravity 5 1 instance 18 exposed
Issued
Dec 17, 2014
Abate by
Jan 21, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(1): An educational program was not provided for all employees to familiarize them with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting:  a)  Davis Bros. Inc., on or about 11/24/14:  The employer did not provide training to employees on the use of fire extinguishers and hazards involved with incipient stage fire fighting.   *ABATEMENT NOTE:  By this date the employer must either correct the alleged violation or implement a Fire Safety Policy; as outlined in 29 CFR 1910.38(a) and .39(a) which includes the evacuation requirements of 29 CFR 1910.157(b).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 7 exposed
Issued
Dec 17, 2014
Abate by
Jan 21, 2015
Penalty
Initial $1,600 · Current $600 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):    a)  Davis Bros. Inc., on or about 11/24/14:  The employer did not provide training to each powered industrial truck operator.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1600

1910.212 A05

Serious Gravity 5 3 instances 2 exposed
Issued
Dec 17, 2014
Abate by
Jan 21, 2015
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:    a)  Compressor Room, on or about 11/24/14:  Compressor fan blades were not adequately guarded.    b)  Outside, on or about 11/24/14:  Compressor fan blades were not adequately guarded.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

View Davis Bros. INC.'s full OSHA safety record →