Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COLTER ENERGY SERVICES USA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of COLTER ENERGY SERVICES USA, INC. in WELL SITE BAZOOKA 1-20H, NEW TOWN, ND 58763 (NAICS 213112). OSHA activity number 340100916.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Colter Energy Services USA, INC. — free Get an email when a new federal OSHA severe-injury report for Colter Energy Services USA, INC. is published. One employer, no account, unsubscribe in one click.
Site address
WELL SITE BAZOOKA 1-20H
City
NEW TOWN
State
ND
ZIP
58763
Mailing
#2 905 30TH STREET, MINOT, ND 58703
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
213112
Employees
189
Ownership type
A

1 citation on file for this inspection.

1910.106 B06

Serious Gravity 5 1 instance 2 exposed
Issued
May 4, 2015
Abate by
May 21, 2015
Penalty
Initial $4,500 · Current $2,250 Reduced
29 CFR 1910.106(b)(6): In locations where flammable vapors may be present, precautions were not taken to prevent ignition by eliminating or controlling sources of ignition.  Sources of ignition may include open flames, lightning, smoking, hot surfaces, frictional heat, sparks (static, electrical, and mechanical), spontaneous ignition, chemical and physical-chemical reactions, and radiant heat:                                                                 OR IN THE ALTERNATIVE     Section 5(a)(1): The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fire and explosion hazards:     (a) On or about November 6, 2014, for the employee engaged in operating a Detroit Diesel Series 60 engine during well servicing operations approximately 19 feet from a tank containing residual crude oil liquids at the Slawson well site identified as Bazooka 1-20H.         Abatement Note: Among other methods, some feasible and acceptable abatement methods to correct these hazards would include following the American Petroleum Institute (API) Recommended Practice 54 which include but are not limited to:   1. 12.1.8 Discharges of oil or gas to the atmosphere should be to a safe area, preferably on the downwind side of the well and a minimum of 100 feet from the well head, open flame, or other sources of ignition. At locations where this recommendation may be impractical, appropriate safety measures should be implemented.     2. In addition to the API, the Association of Energy Services Companies (AESC) has procedures for Hot Work which involves any activity performed in a hazardous location which may introduce an ignition source into a potentially flammable atmosphere.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $4500

View Colter Energy Services USA, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340100916.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.