Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: IDA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of IDA, INC. in 245 HIGHWAY 200, HERON, MT 59844 (NAICS 332710). OSHA activity number 340100957.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch IDA, INC. — free Get an email when a new federal OSHA severe-injury report for IDA, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
IDA, INC.
Site address
245 HIGHWAY 200
City
HERON
State
MT
ZIP
59844
Mailing
245 HIGHWAY 200, HERON, MT 59844
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
20
Ownership type
A

5 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 3 instances 15 exposed
Issued
Mar 25, 2015
Abate by
Apr 20, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Production Floor, Line Ten: On or about November 19, 2014 and times prior, employees were exposed to caught in hazards while working around the unguarded Okuma Horizontal Lathe hydraulic drive assembly.    (b) Production Floor, Line Ten: On or about November 19, 2014 and times prior, employees were exposed to caught in hazards while working around the unguarded Captain L370M hydraulic drive assembly.    (c) Production Floor, Line Three: On or about November 19, 2014 and times prior, employees were exposed to caught in hazards while working around the unguarded Okuma Horizontal Lathe hydraulic drive assembly.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.242 B

Serious Gravity 5 12 instances 15 exposed
Issued
Mar 25, 2015
Abate by
Apr 20, 2015
Penalty
Initial $2,400 · Current $1,440 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment:       (a) Production Floor, Machine Shop: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 65 p.s.i. of unregulated air at the nozzle.       (b) Production Floor, Line One: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (c) Production Floor, Line Two: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (d) Production Floor, Line Three: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (e) Production Floor, Line Four: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (f) Production Floor, Line Five: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (g) Production Floor, Line Six: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (h) Production Floor, Line Seven: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (i) Production Floor, Line Eight: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (j) Production Floor, Line Eight Support: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (k) Production Floor, Line Nine: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.       (l) Production Floor, Line Ten: On or about November 19, 2014 and times prior, employees were exposed to flying parts and pieces and air embolisms while using air nozzles with approximately 85 p.s.i. of unregulated air at the nozzle.
Recent events (2)
  • — I (S) $1440
  • — Z (S) $2400

1910.303 B02

Serious Gravity 5 6 instances 15 exposed
Issued
Mar 25, 2015
Abate by
Apr 20, 2015
Penalty
Initial $1,600 · Current $960 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:       (a) Production Floor, Line One: On or about November 19, 2014 and times prior, employees were exposed to an electrical shock while using a 120 volt junction box designed for internal wall use as an external, permanent power supply.        (b) Production Floor, Lathe Two: On or about November 19, 2014 and times prior, employees were exposed to an electrical shock while using a 120 volt junction box designed for internal wall use as an external, permanent power supply.       (c) Production Floor, Line Three: On or about November 19, 2014 and times prior, employees were exposed to an electrical shock while using a 120 volt junction box designed for internal wall use as an external, permanent power supply.       (d) Production Floor, Line Five: On or about November 19, 2014 and times prior, employees were exposed to an electrical shock while using a 120 volt junction box designed for internal wall use as an external, permanent power supply.       (e) Production Floor, Line Seven: On or about November 19, 2014 and times prior, employees were exposed to an electrical shock while using a 120 volt junction box designed for internal wall use as an external, permanent power supply.       (f) Production Floor, Line Eight: On or about November 19, 2014 and times prior, employees were exposed to an electrical shock while using a 120 volt junction box designed for internal wall use as an external, permanent power supply.    (f) Production Floor, Line Eight: On or about November 19, 2014 and times prior, employees were exposed to electric shock by using a 120 volt four plex box hung from frame connection as a replacement for permanent wiring.
Recent events (2)
  • — I (S) $960
  • — Z (S) $1600

1910.305 F01

Serious Gravity 5 1 instance 10 exposed
Issued
Mar 25, 2015
Abate by
Apr 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(f)(1): Conductors used for general wiring were not insulated:  (a) Production Floor, Machine Shop: On or about November 19, 2014 and times prior, employees exposed to electric shock while using the improperly wired Jet Drill Press Model JDP-15M.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 2 instances 20 exposed
Issued
Mar 25, 2015
Abate by
Apr 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  (a) Machine Shop: On or about November 19, 2014 and times prior, employees were exposed electric shock by using a 208 volt Milwaukee Kearney & Trecker 205 S-12 Vertical Mill that had a lack of adequate strain relief to prevent the direct pull on the conductors.  (b) Production Floor: On or about November 19, 2014 and times prior, employees were exposed electric shock by using a 208 volt FANUC Robodrill that had a lack of adequate strain relief to prevent the direct pull on the conductors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View IDA, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340100957.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.