Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SEW-EURODRIVE INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SEW-EURODRIVE INC. in 2107 HIGH HILL RD., BRIDGEPORT, NJ 08014 (NAICS 333612). OSHA activity number 340102128.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Sew-Eurodrive INC. — free Get an email when a new federal OSHA severe-injury report for Sew-Eurodrive INC. is published. One employer, no account, unsubscribe in one click.
Establishment
SEW-EURODRIVE INC.
Site address
2107 HIGH HILL RD.
City
BRIDGEPORT
State
NJ
ZIP
08014
Mailing
P.O. BOX 481, BRIDGEPORT, NJ 08014
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333612
Employees
600
Ownership type
A

3 citations on file for this inspection.

1910.134 E01

Serious Gravity 1 1 instance 1 exposed
Issued
Dec 31, 2014
Abate by
Jan 28, 2015
Penalty
Initial $3,000 · Current $2,250 Reduced
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  a)  Sew-Eurodrive Inc. Paint booth:  Employees required to use the 3M Versaflo M-100 Powered Air Purifying Respirators equipped with TR 3710N  High Efficiency Particulate (HE) filter for painting operations were not provided with a medical evaluation to determine the employees ability to use it.  Condition noted on or about 11/21/2014.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3000

1910.303 B02

Serious Gravity 1 2 instances 4 exposed
Issued
Dec 31, 2014
Abate by
Jan 28, 2015
Penalty
Initial $3,000 · Current $2,250 Reduced
29 CFR 1910.303(b)(2):   Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a) Sew-Eurodrive - Motor assembly area:  Power strips were used as permanent outlets to power a vestil lift machine no S/N available, observed on or about 11/21/2014.  b) Sew-Eurodrive - near the paint booth area:  Power strips were used as permanent outlets to power an extension cord connected to the electrical outlet, observed on or about 11/21/2014.
Recent events (2)
  • — I (S) $2250
  • — Z (S) $3000

1910.305 G01 IV A

Serious Gravity 1 2 instances 4 exposed
Issued
Dec 31, 2014
Abate by
Jan 28, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Sew-Eurodrive - Motor assembly area:  Flexible cords were used to power a vestil lift machine no S/N available, observed on or about 11/21/2014.  b) Sew-Eurodrive - near the paint booth area:  Flexible cords were used to power a power strip which was connected to a fan, observed on or about 11/21/2014.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Sew-Eurodrive INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340102128.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.