CHEEKTOWAGA, NY ·
OSHA Inspection: LMP MAINTENANCE INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of LMP MAINTENANCE INC. in 48 BARBARA PLACE, CHEEKTOWAGA, NY 14225 (NAICS 236118). OSHA activity number 340106228.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- LMP MAINTENANCE INC.
- Site address
- 48 BARBARA PLACE
- City
- CHEEKTOWAGA
- State
- NY
- ZIP
- 14225
- Mailing
- 2940 DELAWARE AVENUE SUITE 202, KENMORE, NY 14217
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236118
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Jan 2, 2015
- Penalty
- Initial $1,200 · Current $900 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 11/25/14 at a roof replacement project located at 48 Barbara Place, Cheektowaga, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $900
- · Z (S) $1200
1926.451 E01
- Issued
- Jan 2, 2015
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): A means of access for scaffold platforms more than 2 feet (0.6 m) above or below a point of access, such as portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used: a) On or about 11/25/14 at a roof replacement project located at 48 Barbara Place, Cheektowaga, New York; employees were using a ladder jack scaffold, with the scaffold brackets and platform to the outside of the supporting ladders. The employees had to access the platform by climbing the supporting ladders and climbing around the bracket and platform. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1200
- · Z (S) $1600
1926.451 F06
- Issued
- Jan 2, 2015
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6): a) On or about 11/25/14 at a roof replacement project located at 48 Barbara Place, Cheektowaga, New York; employees working from an aluminum ladder jack scaffold stage placed the stage approximately 1 foot away from the electric service cable. Minimum clearance for 300 volts or less is 3 feet. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1200
- · Z (S) $1600
1926.451 G01 I
- Issued
- Jan 2, 2015
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 11/25/14 at a roof replacement project located at 48 Barbara Place, Cheektowaga, New York; employees were using a ladder jack scaffold to perform work and access the roof. The platform height was approximately 16 feet and here was no personal fall arrest system in place. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1500
- · Z (S) $2000
1926.501 B11
- Issued
- Jan 2, 2015
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 11/25/14 at a roof replacement project located at 48 Barbara Place, Cheektowaga, New York; employees were tearing shingles off from a roof with a 12 in 12 pitch and an eave height of approximately 16 feet. There were no fall protection systems in place. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $1500
- · Z (S) $2000
More inspections in this industry (NAICS 236118)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340106228.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.