DENVER, CO —
OSHA Inspection: FORMTIGHT, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of FORMTIGHT, INC. in 11600 E. 51ST AVE., DENVER, CO 80239 (NAICS 326112). OSHA activity number 340107382.
Where did this inspection happen?
- Establishment
- FORMTIGHT, INC.
- Site address
- 11600 E. 51ST AVE.
- City
- DENVER
- State
- CO
- ZIP
- 80239
- Mailing
- 11600 E. 51ST AVE., DENVER, CO 80239
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326112
- Employees
- 59
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $3500.00 · Current $1750.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Formtight, Inc. at 11600 E 51st Ave., Denver, CO 80239: On or before November 26th, 2014, the employer did not ensure that an energy control program, specific to the establishment, which included energy control procedures, employee training and periodic inspections was established. This condition exposed employees conducting servicing or maintenance operations to hazards associated with unexpected energizing, startup or release of stored energy.
Recent events (2)
- — I (S) $1750
- — Z (S) $3500
1910.147 C04 II C
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(4)(ii)(C): The energy control procedure did not clearly and specifically outline the steps for placement, removal and transfer of lockout devices or tagout devices and the responsibility for them. a) Formtight, Inc. at 11600 E 51st Ave., Denver, CO 80239: On or before November 26th, 2014, the employer did not ensure that specific steps were developed for the placement, removal and transfer of lockout devices, with designated responsibility for them, in that alternate keys for lockout devices were readily available for any employee to use. This condition exposed employees to hazards associated with uncontrolled hazardous energy.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections at FORMTIGHT, INC.
DENVER, CO—2024-07-24 00:00:00
FORMTIGHT INC.
DENVER, CO—2021-10-19 00:00:00
FORMTIGHT, INC.
DENVER, CO—2021-08-11 00:00:00
FORMTIGHT, INC.
View FORMTIGHT, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 326112)
SUWANEE, GA—2026-06-25
ROSSINI NORTH AMERICA, LLC
ORANGEBURG, SC—2026-06-17
77529 - INDEVCO INC OF NORTH AMERICA
CONOVER, NC—2026-05-13
161214 - PREGIS PROTECTIVE FILMS - COATINGS, INC.
BIOLA, CA—2026-05-07
POLYCELL PACKAGING CORPORATION
RHINELANDER, WI—2026-05-06
PRINTPACK INC.
More inspections in CO
CASTLE ROCK, CO—2026-07-10
MASTER MAGNETICS, INC.
STRASBURG, CO—2026-07-08
JUNIOR ROOFING LLC
FORT COLLINS, CO—2026-07-08
EDWARDS SEMICONDUCTOR SOLUTIONS LLC
CENTENNIAL, CO—2026-07-08
JORDY CONSTRUCTION
HIGHLANDS RANCH, CO—2026-07-08
HOWELL CONSTRUCTION
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340107382.