OSHA Inspection: TCB BUILDERS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of TCB BUILDERS in 4445 YUMA NW, WASHINGTON, DC 20013 (NAICS 238170). OSHA activity number 340107929.

Watch TCB Builders — free Get an email when a new federal OSHA severe-injury report for TCB Builders is published. One employer, no account, unsubscribe in one click.
Establishment
TCB BUILDERS
Site address
4445 YUMA NW
City
WASHINGTON
State
DC
ZIP
20013
Mailing
14221 ALDERTON RD, SILVER SPRING, MD 20906
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
10
Ownership type
A

4 citations on file for this inspection.

1926.451 B05 II

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(b)(5)(ii): The end of a platform greater than 10 feet in length extended over its support more than 18 inches and the platform was not designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilivered end.  On November 10, 2014, and at times prior thereto: rear area of home: employees were working off a pump-jack scaffold in which the working platform extended 36 inches beyond the support exposing employees to 35 foot fall to ground level.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $2800

1926.451 C02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames,  or uprights did not bear on base plates, mud sills or other adequate firm foundation:  a) On November 10, 2014 and at times prior thereto: rear area of home: employees were working off a pump-jack scaffold in which one of the poles was not placed on a base plate to prevent it from sinking into the ground.   Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $2800

1926.451 G01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:  On November 10, 2014 and at times prior thereto: rear area of home: employees were working off a pump-jack scaffold without a personal arrest system in place to protect them from falling 35 feet to ground level while installing the vinyl siding on the residential home.    Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic or video evidence of abatement or other written records.
Recent events (1)
  • — Z (S) $2800

1926.1053 B01

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $2800.00
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed:   a) On November 10, 2014 and at times prior thereto; rear of residential home; the ladder used to access the work area was 12 inches above the working platform exposing them to a fall hazard of 35 feet to ground level while accessing or stepping off the ladder to the platform.
Recent events (1)
  • — Z (S) $2800

MACY'S