OSHA Inspection: P&C FENCE COMPANY INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of P&C FENCE COMPANY INC. in 60 RADEL ST, BRIDGEPORT, CT 06607 (NAICS 332323). OSHA activity number 340108257.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch P&C Fence Company INC. for free Get an email when a new federal OSHA severe-injury report for P&C Fence Company INC. is published. One employer, no account, unsubscribe in one click.
Site address
60 RADEL ST
City
BRIDGEPORT
State
CT
ZIP
06607
Mailing
60 RADEL ST, BRIDGEPORT, CT 06607
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
10
Ownership type
Private (A)

17 citations on file for this inspection.

1910.37 A03

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $2,000 · Current $1,280 Reduced
29 CFR 1910.37(a)(3): Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route.     SHOP: The emergency exit located next to the overhead door was blocked by the electrical forklift battery charging station, the air hose and mechanical ventilation unit for the spray paint room, five (5) propane tanks and a mobile electrical storage cart.
Recent events (2)
  • · I (S) $1280
  • · Z (S) $2000

1910.157 C01

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $1,200 · Current $750 Reduced
29 CFR 1910.157(c)(1): The employer shall provide portable fire extinguishers and shall mount, locate and identify them so that they are readily accessible to employees without subjecting the employees to possible injury.    SHOP: The Kidde 20lb dry chemical fire extinguisher, energized and ready for use was found on the floor underneath a work table.
Recent events (2)
  • · I (S) $750
  • · Z (S) $1200

1910.157 E02

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(2): Portable extinguishers or hose used in lieu thereof under paragraph (d)(3) of this section shall be visually inspected monthly.  SHOP: The Kidde 20lb dry chemical fire extinguisher, energized and ready for use was not inspected on a monthly basis since at least 2009.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.157 E03

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Jun 4, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.157(e)(3): The employer shall assure that portable fire extinguishers are subjected to an annual maintenance check. Stored pressure extinguishers do not require an internal examination. The employer shall record the annual maintenance date and retain this record for one year after the last entry or the life of the shell, whichever is less. The record shall be available to the Assistant Secretary upon request.    SHOP:  The following fire extinguishers in the fabrication area were not inspected. These include (but are not limited to):   1. Amerex ABC dry chemical extinguisher, serial number A24077435   2. Amerex ABC dry chemical extinguisher, serial number A24077437   3. Kidde 20lb dry chemical fire extinguisher, serial number unreadable
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
Jul 31, 2015
Penalty
Initial $1,200 · Current $750 Reduced
29 CFR 1910.178(l)(1)(i): The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    SHOP: The employer did not ensure that the employee, authorized and allowed to operate powered industrial forklifts was trained and evaluated for the specific type(s) of forklifts in the facility.
Recent events (2)
  • · I (S) $750
  • · Z (S) $1200

1910.178 L01 II

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
Jul 31, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer shall ensure that each operator has successfully completed the training required by this paragraph (l), except as permitted by paragraph (l)(5).    SHOP: The employer did not ensure that employees, authorized and allowed to operate powered industrial forklifts had completed the forklift training and evaluated prior to allowing the employees to operate the specific type(s) of forklifts in the facility.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 L06

Serious Gravity 1 1 instance 2 exposed
Issued
Apr 22, 2015
Abate by
Jul 31, 2015
Penalty
Initial $1,200 · Current $750 Reduced
29 CFR 1910.178(l)(6): Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.    SHOP: The employer did not ensure through written certification that the employees, authorized and allowed to operate powered industrial forklifts were properly trained and evaluated.
Recent events (2)
  • · I (S) $750
  • · Z (S) $1200

1910.212 A03 II

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
May 11, 2015
Penalty
Initial $2,000 · Current $1,280 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.    SHOP: The point-of operation of the Scotchman model 6509 Ironworker, serial number 23291985 was not adequately guarded to prevent the operator/employees from having access into the point of operation.
Recent events (2)
  • · I (S) $1280
  • · Z (S) $2000

1910.215 A02

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1910.215(a)(2): Guard design. The safety guard shall cover the spindle end, nut, and flange projections.     SHOP: The right side grinding wheel of the DeWalt model DW758 bench grinder, serial number 200319-YL0128 was missing the safety guard, exposing employees to the rotating spindle nut, end and flange.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $2800

1910.215 A04

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(a)(4): Work rests. On offhand grinding machines, work rests shall be used to support the work. They shall be of rigid construction and designed to be adjustable to compensate for wheel wear. Work rests shall be kept adjusted closely to the wheel with a maximum opening of one-eighth inch to prevent the work from being jammed between the wheel and the rest, which may cause wheel breakage. The work rest shall be securely clamped after each adjustment. The adjustment shall not be made with the wheel in motion.  SHOP: The work rest for the right side grinding wheel of the DeWalt model DW758 bench grinder, serial number 200319-YL0128 was adjusted completely away from the grinding wheel.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.215 B09

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel.   SHOP: The tongue guard for the right side grinding wheel of the DeWalt model DW758 bench grinder, serial number 200319-YL0128 was adjusted completely away from the grinding wheel.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.219 C04 I

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(I): Projecting shaft ends. Projecting shaft ends shall present a smooth edge and end and shall not project more than one-half the diameter of the shaft unless guarded by nonrotating caps or safety sleeves.  SHOP: The shaft end and nut for the wire brush that was on the left side of the DeWalt model DW758 bench grinder, serial number 200319-YL0128 were not guarded.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.178 F02

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $2,400 · Current $1,590 Reduced
29 CFR 1910.178(f)(2): The storage and handling of liquefied petroleum gas fuel shall be in accordance with NFPA Storage and Handling of Liquefied Petroleum Gases (NFPA No. 58-1969), which is incorporated by reference as specified in Sec. 1910.6.    SHOP: The five (5) propane fuel bottles for the powered industrial forklift (PIT) were stored in the area between the overhead door and emergency exit door where the electrical forklift was normally parked for charging overnight.
Recent events (2)
  • · I (S) $1590
  • · Z (S) $2400

1910.253 B02 II

Serious Gravity 5 2 instances 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii): Inside of buildings, assigned storage spaces shall be located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders shall not be kept in unventilated enclosures such as lockers and cupboards.  Metal Fabrication Area: The following partially full compressed gas cylinders were left free standing in areas where other activities were frequent, and no safe means or methods were utilized to protect them from physical damage:  1. One Oxygen cylinder. 2. One Compressed gas cylinder.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 B02 I

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $2,800 · Current $1,800 Reduced
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    Fabrication Area: The duplex outlet box, into which the attachment plug of the Rockwell drill press was plugged was missing the cover, exposing the internal wiring.
Recent events (2)
  • · I (S) $1800
  • · Z (S) $2800

1910.305 G01 IV C

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(C):  Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used where run through doorways, windows, or similar openings;  SHOP: The yellow/black heavy duty extension cord, used to energize the engine block heater on a diesel truck was run across the floor and through the overhead door exposing the cord to physical damage from powered industrial forklift traffic.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.305 G01 IV D

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 22, 2015
Abate by
Apr 30, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(D):  Unless specifically permitted otherwise in paragraph (g)(1)(ii) of this section, flexible cords and cables may not be used where attached to building surfaces;  SHOP: A yellow/black heavy duty extension cord, used to energize the engine block heater on a diesel truck was secured to a permanent installed railing in front of the Scotchman Ironworker press.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

View P&C Fence Company INC.'s full OSHA safety record →