THEODORE, AL —
OSHA Inspection: ALABAMA HEAT EXCHANGERS, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ALABAMA HEAT EXCHANGERS, INC. in 5751 LARUE STEINER RD., THEODORE, AL 36582 (NAICS 332420). OSHA activity number 340108653.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALABAMA HEAT EXCHANGERS, INC.
- Site address
- 5751 LARUE STEINER RD.
- City
- THEODORE
- State
- AL
- ZIP
- 36582
- Mailing
- P. O. BOX 174, THEODORE, AL 36590
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332420
- Employees
- 23
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.134 I05 IV
- Issued
- Feb 20, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(5)(iv): The employer did not ensure that compressors used to supply breathing air to respirators were constructed and situated so as to have a tag maintained at the compressor containing the most recent change date and the signature of the person authorized by the employer to perform the change: a)Sandblasting area located in shop yard: On or about November 20, 2014, and prior to, employees were exposed to inhalation and asphyxiation hazards from required use of a Nova 2000 hood respirator that has breathing air generated from a Sullair oil based compressor without documenting filter change information on breathing air filter pot while conducting sandblasting job tasks.
Recent events (1)
- — Z (O) $0
1910.134 I07
- Issued
- Feb 20, 2015
- Abate by
- Mar 2, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(i)(7): For oil-lubricated compressors, the employer shall use a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels. If only high-temperature alarms are used, the air supply shall be monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm. a)Sandblasting area located in shop yard: On or about November 20, 2014, and prior to, employees were exposed to inhalation and asphyxiation hazards from required use of a Nova 2000 hood respirator that has breathing air generated from a Sullair oil based compressor that does not have a Carbon Monoxide alarm or temperature alarm while conducting sandblasting job tasks.
Recent events (1)
- — Z (O) $0
More inspections at Alabama Heat Exchangers, INC.