COLUMBUS, OH ·
OSHA Inspection: BALL CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BALL CORPORATION in 2690 CHARTER ST, COLUMBUS, OH 43228 (NAICS 332431). OSHA activity number 340108976.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BALL CORPORATION
- Site address
- 2690 CHARTER ST
- City
- COLUMBUS
- State
- OH
- ZIP
- 43228
- Mailing
- 2690 CHARTER ST, COLUMBUS, OH 43228
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332431
- Employees
- 158
- Ownership type
- Private (A)
Citations
8 citations on file for this inspection.
1910.23 A08
- Issued
- Feb 25, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $2,550 · Current $2,040 Reduced
General-duty citation text
29 CFR 1910.23(a)(8): Every floor hole into which persons can accidentally walk shall be guarded by either: 29 CFR 1910.23(a)(8)(i): A standard railing with standard toeboard on all exposed sides, or 29 CFR 1910.23(a)(8)(ii): A floor hole cover of standard strength and construction. While the cover is not in place, the floor hole shall be constantly attended by someone or shall be protected by a removable standard railing. Ball Corporation, 2690 Charter Street, Columbus Ohio workplace: a. On or about December 1, 2014, the Seamer elevator floor hole was not protected by standard railing or a floor hole cover, b. On or about December 1, 2014, the Feeder elevator floor hole was not protected by standard railing or a floor hole cover, and c. On or about December 2, 2014, the Necker elevator floor hole was not protected by standard railing or a floor hole cover.
Recent events (2)
- · I (O) $2040
- · Z (S) $2550
1910.23 C01
- Issued
- Feb 25, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $4,250 · Current $3,400 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder: a. Ball Corporation, 2690 Charter Street, Columbus Ohio workplace: On or about December 2, 2014, the employer had not protected with standard railing (or equivalent protection) open sided platforms on the mezzanine above the Weld department Line 1 (around the corner from the Necker elevator.) Due to this condition, employees are exposed to a fall hazard of approximately ten feet.
Recent events (2)
- · I (S) $3400
- · Z (S) $4250
1910.147 D03
- Issued
- Feb 25, 2015
- Abate by
- Oct 1, 2015
- Penalty
- Initial $3,400 · Current $2,720 Reduced
General-duty citation text
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): a. Ball Corporation, 4960 Charter Street, Columbus Ohio workplace: On or about December 1, 2014, the employer did not require energy isolating device use to in a manner to isolate machine energy sources in the Weld department. When performing required daily duties on five production line Welders covered by this part, such as clearing jams, making adjustments and making checks, energy source isolation is inadequately performed by use of an emergency stop with a tag placed around the emergency stop fixture. Due to this condition, employees are exposed to caught-in hazards from potentially moving parts.
Recent events (2)
- · I (S) $2720
- · Z (S) $3400
1910.219 C02 I
- Issued
- Feb 25, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $3,400 · Current $2,720 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): Shafting. Guarding. All exposed parts of horizontal shafting seven (7) feet or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires. a. Ball Corporation, 2690 Charter Street, Columbus Ohio workplace: On or about December 1, 2014, on the Weld department mezzanine, the shafts and pulleys at the Seamer elevator were not enclosed or otherwise guarded.
Recent events (2)
- · I (S) $2720
- · Z (S) $3400
1910.219 D01
- Issued
- Feb 25, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Guarding. Pulleys, any parts of which are seven (7) feet or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than six feet six inches (6 ft. 6 in.) from the floor or platform may be guarded with a disk covering the spokes. a. Ball Corporation, 2690 Charter Street, Columbus Ohio workplace: On or about December 1, 2014, on the Weld department mezzanine, the shafts and pulleys at the Seamer elevator were not enclosed or otherwise guarded.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.303 G02 I
- Issued
- Feb 25, 2015
- Abate by
- Mar 9, 2015
- Penalty
- Initial $4,250 · Current $3,400 Reduced
8870
General-duty citation text
29 CFR 1910.303(g)(2)(i): Except as elsewhere required or permitted by this standard, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by use of approved cabinets or other forms of approved enclosures or by any of the following means listed in (A)-(D): a. Ball Corporation, 2690 Charter Street, Columbus Ohio workplace: On or about December 1, 2014, the connection for the conduit attachment to the electric motor that powers the Feeder for the 80 Beader machine was pulled out/apart from the motor. Due to this condition, employees are exposed to an electrical contact hazard and increased risk for electrocution.
Recent events (2)
- · I (S) $3400
- · Z (S) $4250
1910.212 A02
- Issued
- Feb 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(2): Machine guarding. General requirements for machine guards. Guards shall be affixed to the machine where possible and secured elsewhere if for any reason attachment to the machine is not possible. The guard shall be such that it does not offer an accident hazard in itself. Ball Corporation, 2690 Charter Street, Columbus Ohio workplace: On or about December 1, 2014, in the Weld department, at the following locations machine guarding was secure and affixed properly: a. at the Line 1 Stacker; a barrier guard was not secure and properly affixed. Allen head screws were missing and/or loose. b. at the Line 1 Slitter adjacent to the Slitter door interlock: the feeder barrier guard housing was not secure and affixed. An allen head screw was missing.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.305 B01 II
- Issued
- Feb 25, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Cabinets, boxes, and fittings. Unused openings in cabinets, boxes, and fittings shall be effectively closed. Ball Corporation, 2690 Charter Street, Columbus Ohio workplace: On or about December 1, 2014, Unused openings in cabinets were not effectively closed for the following equipment locations: a. The Weld Department Line 1 Stacker adjacent to the Keyence defined field electronic guarding control; b. The Press Department SFADM Line 1 Feeder power supply box.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections at Ball Corporation
View Ball Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332431)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340108976.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.