BOWDON, GA ·
OSHA Inspection: YATES DOORS
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of YATES DOORS in 4736 HIGHWAY 100 SOUTH, BOWDON, GA 30108 (NAICS 321911). OSHA activity number 340111145.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- YATES DOORS
- Site address
- 4736 HIGHWAY 100 SOUTH
- City
- BOWDON
- State
- GA
- ZIP
- 30108
- Mailing
- 4736 HIGHWAY 100 SOUTH, BOWDON, GA 30108
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321911
- Employees
- 3
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.178 L01 I
- Issued
- Dec 16, 2014
- Abate by
- Feb 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) The employer had not ensured that each employee operating the Komatsu Type G (Model No. FG25C11, Serial No. 458123) was competent to operate the powered industrial truck.
Recent events (1)
- · Z (O) $0
1910.178 P01
- Issued
- Dec 16, 2014
- Abate by
- Feb 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s) a) The employer allowed employees to operate the Komatsu Type G (Model No. FG25C11, Serial No. 458123) while it was found to be in need of repair. Employees operated the forklift while the horn was defective and in need of repair.
Recent events (1)
- · Z (O) $0
More inspections at Yates Doors
View Yates Doors's full OSHA safety record →
More inspections in this industry (NAICS 321911)
More inspections in GA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340111145.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.