RINGOES, NJ —
OSHA Inspection: HED INTERNATIONAL, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HED INTERNATIONAL, INC. in 449 ROUTE 31 NORTH, RINGOES, NJ 08551 (NAICS 333994). OSHA activity number 340111699.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HED INTERNATIONAL, INC.
- Site address
- 449 ROUTE 31 NORTH
- City
- RINGOES
- State
- NJ
- ZIP
- 08551
- Mailing
- PO BOX 246, RINGOES, NJ 08551
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333994
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.106 E02 IV D
- Issued
- Feb 5, 2015
- Abate by
- Mar 4, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.106(e)(2)(iv)(d): Flammable liquids were not drawn from or transferred into vessel(s), container(s), or portable tank(s) within a building through a closed piping system, from safety cans, by means of a device drawing through the top, or from a container or portable tank by gravity through an approved self-closing valve: a/ HED/Ringoes NJ Site: Shop Area: Safety can(s) were not provided and used to store and dispense Category 2 flammable liquid(s) with flash point less than 100 degrees F including but not limited Klean Strip Lacquer thinner (flash point < 15 F). Observed on/or about 12/02/2014.
Recent events (1)
- — Z (S) $1600
1910.253 B04 III
- Issued
- Feb 5, 2015
- Abate by
- Mar 4, 2015
- Penalty
- Initial $1,600 · Current $1,600
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a/ HED/Ringoes NJ Site: Shop Area: One Standard size (250 cu.ft.) Oxygen and One Acetylene tank (in storage) were not separated by a minimum 20 ft. or other approved means. Observed on/or about 12/02/2014.
Recent events (1)
- — Z (S) $1600
1910.134 C02 I
- Issued
- Feb 5, 2015
- Abate by
- Mar 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(2)(i): Where the employer provided respirators for employees to use voluntarily, the employer did not provide the respirator users with the information contained in Appendix D to this section ("Information for Employees Using Respirators When Not Required Under the Standard"): Hed International, Inc, Inc. - NJ site: Employee(s) were not provided with Appendix D when N95 NIOSH approved filtering face piece respirators were voluntarily worn by employees. Observed on or about 12/02/14.
Recent events (1)
- — Z (O) $0
1910.157 C01
- Issued
- Feb 5, 2015
- Abate by
- Mar 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a/ HED/Ringoes NJ Site: Shop Area: Portable fire extinguishers located within the Shop area were not accessible due to being blocked by materials such as, but not limited to Oxygen/Acetylene cylinders, plastic buckets, and rubber hoses. Observed on/or about 12/02/2014.
Recent events (1)
- — Z (O) $0
1910.1200 H03 IV
- Issued
- Feb 5, 2015
- Abate by
- Mar 4, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(h)(3)(iv): The details of the hazard communication program developed by the employer, did not include an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employee could obtain and use the appropriate hazard information: Hed International, Inc, Inc. - NJ site: Employee(s) did not receive updated training on the Revision to the Hazard Communication Program which include, but is not limited to the updating of Safety Data Sheet(s), labeling, and pictogram use. Observed on or about 12/02/14.
Recent events (1)
- — Z (O) $0
More inspections at HED International, INC.
View HED International, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 333994)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340111699.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.