Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EDELMANN PROVISION COMPANY

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of EDELMANN PROVISION COMPANY in 10000 MARTINS WAY, HARRISON, OH 45030 (NAICS 311613). OSHA activity number 340111707.

Watch Edelmann Provision Company — free Get an email when a new federal OSHA severe-injury report for Edelmann Provision Company is published. One employer, no account, unsubscribe in one click.
Site address
10000 MARTINS WAY
City
HARRISON
State
OH
ZIP
45030
Mailing
10000 MARTINS WAY, HARRISON, OH 45030
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311613
Employees
85
Ownership type
A

4 citations on file for this inspection.

1910.23 C01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $500.00 Reduced
29 CFR 1910.23(c)(1): Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides,      a) The overhead platform used to add ingredients for the mixer was not equipped with a intermediate railing to prevent employees exposure to falls.    b) The ingredients elevator was not equipped with a railing system to prevent material from falling off to the floor below.
Recent events (2)
  • — I (O) $500
  • — Z (S) $2800

1910.147 D03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $4900.00
29 CFR 1910.147(d)(3): Machine or equipment isolation. All energy isolating devices that are needed to control the energy to the machine or equipment shall be physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s).    a) On or about 30 November, 2014 employees were removing plastic bag from mixer.  The power to the mixing machine AMFEC model #503, was not shut off and an employee's arm was caught in the injection door of the machine.
Recent events (2)
  • — I (S) $4900
  • — Z (S) $4900

1910.147 D04 I

Serious Gravity 10 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $0.00 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices shall be affixed to each energy isolating device by authorized employees.    a) On or about 30 November, 2014 employees were removing plastic bag from mixer.  Energy isolating devices were not attached to the energy isolating device on the AMFEC mixer model #510 machine, to prevent employee's contact with running and moving parts.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4900

1910.147 C07 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $4900.00 · Current $3500.00 Reduced
29 CFR 1910.147(c)(7)(i): The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:    a) On or about November 30, 2014 employees who were involved in removal of jammed material inside of the AMFEC 510 mixer, they were not trained as authored employees when their duties included servicing and/or maintenance of equipment.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $4900