Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,124Inspections Most recent open 2026-08-25 Last loaded 2026-08-28

OSHA Inspection: GENTEX CORPORATION

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of GENTEX CORPORATION in 324 MAIN STREET, SIMPSON, PA 18407 (NAICS 315991). OSHA activity number 340113281.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gentex Corporation for free Get an email when a new federal OSHA severe-injury report for Gentex Corporation is published. One employer, no account, unsubscribe in one click.
Establishment
GENTEX CORPORATION
Site address
324 MAIN STREET
City
SIMPSON
State
PA
ZIP
18407
Mailing
PO BOX 315, CARBONDALE, PA 18407
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
315991
Employees
479
Ownership type
Private (A)

2 citations on file for this inspection.

1910.106 E06 I

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $7,000 · Current $7,000

Hazardous substances 2460

29 CFR 1910.106(e)(6)(i): Adequate precautions were not taken to prevent the ignition of flammable vapors from sources such as open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat:  a) Day Mix Room:  Employees poured a metal bucket that contained a liquid toluene/resin mix directly into the Day mixing tank that contained approximately 70 gallons of the flammable liquid, toluene.  The employer did not ensure that the metal bucket was bonded and/or grounded to prevent static discharge during the pouring of this liquid mixture, on or about 12/3/2014.  b) Day Mix Room:  Employees poured/dumped liquid and solid chemicals directly into the Day mixing tank that contained approximately 70 gallons of the flammable liquid, toluene.  The employer did not ensure that employees wore the available anti-static wrist grounding straps and/or other static control mechanisms (e.g., static dissipative footwear, anti-static or conductive clothing) to prevent static discharge from the body.  The employer did not ensure that the metal grounding plugs on the available anti-static wrist grounding straps were free from an accumulation of residue that would prevent successful metal to metal grounding, on or about 12/3/2014.  c) Day Mix Room:  Employees dumped non-conductive cardboard boxes and non-conductive paper bags that contained solid bulk and powdered chemicals directly into the Day mixing tank that contained approximately 70 gallons of the flammable liquid, toluene.  The employer did not ensure that employees used the available intermediate chemical load chute, with attached nitrogen inerting, on the Day mixer tank opening, to eliminate the explosive toluene vapors and prevent the ignition of flammable vapors, on or about 12/3/2014.  d) Day Mix Room:  Employees poured/dumped liquid and solid chemicals directly into the Day mixing tank that contained approximately 70 gallons of the flammable liquid, toluene.  The employer did not ensure that employees turned on the valve that provided nitrogen to inert the headspace of the Day mixer tank and chemical load chute, prior to chemical additions to the day mixer, to eliminate the explosive toluene vapors and prevent the ignition of flammable vapors, on or about 12/3/2014.  ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (S) $7000
  • · Z (S) $7000

1910.132 A

Other-than-serious 1 instance 2 exposed
Issued
Mar 30, 2015
Abate by
May 2, 2015
Penalty
Initial $7,000 · Current $3,000 Reduced

Hazardous substances 2460

29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    a) Day Mix Room:  Employees poured/dumped liquid and solid chemicals directly into the Day mixing tank that contained approximately 70 gallons of the flammable liquid, toluene.  The employer did not ensure that these employees wore fire retardant full-body protection to protect them from the fire hazard created by ignition of flammable vapors, on or about 12/3/2014.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • · I (O) $3000
  • · Z (S) $7000

View Gentex Corporation's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340113281.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.