OSHA Inspection: SCHROEDER INDUSTRIES INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCHROEDER INDUSTRIES INC in 5620 BUSINESS PARK, SAN ANTONIO, TX 78218 (NAICS 333311). OSHA activity number 340117589.

Watch Schroeder Industries INC — free Get an email when a new federal OSHA severe-injury report for Schroeder Industries INC is published. One employer, no account, unsubscribe in one click.
Site address
5620 BUSINESS PARK
City
SAN ANTONIO
State
TX
ZIP
78218
Mailing
5620 BUSINESS PARK, SAN ANTONIO, TX 78218
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333311
Employees
90
Ownership type
A

5 citations on file for this inspection.

1910.212 B

Serious Gravity 5 5 instances 2 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving:  On or about December 03, 2014, employee were exposed to struck-by hazards within the machine maintenance shop while the following fixed items of industrial equipment were found not to be securely anchored in order to prevent inadvertent or unforeseen walking or movement of the machinery:  a) Along the center area of the machine maintenance shop a 2 Bridgeport milling machines were not securely anchored.  b) Along the center area of the machine maintenance shop a Seedoorf Acme spot welding machine model 8280, S.N. R101910 was not securely anchored.  c) Along the center area of the welding shop a Jet drill press model 354221, S.N. 13010933 was not securely anchored.  d) Along the center area of the welding shop an Acme spot welding machine type PTOP-6-50, S.N. 1G173  was not securely anchored.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work:  Along the welding work area, on or about December 03, 2014, an employee was exposed to the caught hazards while using a Craftsman 6-inch bench grinder model number 319.190400 S.N. 9008150 to polish a metal threaded tube without having a work rest attached.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.253 B02 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2800.00 · Current $1680.00 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:  Along the welding work area, on or about December 03, 2014, an welding employee was exposed to the hazards of struck-by while working around approximately 17 compressed gas cylinders containing chemicals such as oxygen and acetylene that were not secured and stored.
Recent events (2)
  • — I (S) $1680
  • — Z (S) $2800

1910.305 B01 II

Serious Gravity 5 5 instances 2 exposed
Issued
Penalty
Initial $3500.00 · Current $2100.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:  Along the production floor area, on or about December 03, 2014, and at times prior thereto, employees were exposed to electrical shock hazards of 120 volts from unused openings along the bottom and sides of the electrical distribution panel boxes that were not effectively closed:  a) Along the east side wall of the production floor power enclosure no. AW59541 controlling the electrical power to the AEC plastic molding machine.  b) Along the center north west side of the production, the fixed power enclosure Siemens model E2396 controlling the electrical power various outlets, lighting units and a Mazak molding machine.  c) Along the center side wall of the production next to the welding area, the fixed power enclosure Square D model QOC42US controlling the electrical power to the lighting fixtures, outlets, and Acme spot welding machines.  d) Along the north side wall of the production the fixed power enclosure GE model 72938 controlling the electrical power to the cooler gfi, roof gfi, forklift charger, night lighting, electrical outlets a Tapmatic model SPD7 and a Sear Craftsman 15" drilling machine.  e) Along the south side wall next to the welding area the fixed power enclosure Square D model QOC42US controlling the electrical power to the lighting fixtures, outlets, wall tumble and plaining machine.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3500

1910.303 G01

Other-than-serious 2 instances 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  Along the production floor, on or about December 03, 2014, the following electrical panel enclosures were found to be covered or partly covered exposing the employees, in the event of an emergency, to limited or no access to the electrical panel disconnects or breaker panels:  a) A General Electric panel enclosure was located along the north wall of the production floor identified to control the main switch for a mold machine labeled TM-2.  b) A Square D panel enclosure model QOC24US located along the center area of the production floor labeled to control work tables 1, 2 and 3.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View SCHROEDER INDUSTRIES INC's full OSHA safety record →