Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,201Inspections Most recent open 2026-08-31 Last loaded 2026-09-03

OSHA Inspection: SNAP KITCHEN #1, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SNAP KITCHEN #1, LLC in 4616 TRIANGLE AVENUE, SUITE 200, AUSTIN, TX 78751 (NAICS 311991). OSHA activity number 340120708.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Snap Kitchen #1, LLC for free Get an email when a new federal OSHA severe-injury report for Snap Kitchen #1, LLC is published. One employer, no account, unsubscribe in one click.
Site address
4616 TRIANGLE AVENUE, SUITE 200
City
AUSTIN
State
TX
ZIP
78751
Mailing
4616 TRIANGLE AVENUE, SUITE 200, AUSTIN, TX 78751
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311991
Employees
45
Ownership type
Private (A)

4 citations on file for this inspection.

1910.138 A

Serious Gravity 1 1 instance 6 exposed
Issued
Feb 5, 2015
Abate by
Feb 20, 2015
Penalty
Initial $2,700 · Current $1,350 Reduced
29 CFR 1910.138(a): Appropriate hand protection was not used when employee's hands were exposed to hazards such as those from skin absorption of harmful substances; severe cuts or lacerations; severe abrasions; punctures; chemical burns; thermal burns; and harmful temperature extremes.    On or about 5 December 2014, and at times prior thereto, 6 employees use kitchen knives to prepare food without the use of hand protection, exposing the workers to an amputation hazard.
Recent events (2)
  • · I (S) $1350
  • · Z (S) $2700

1910.303 B07 IV

Serious Gravity 1 1 instance 8 exposed
Issued
Feb 5, 2015
Abate by
Feb 11, 2015
Penalty
Initial $2,700 · Current $1,350 Reduced
29 CFR 1910.303(b)(7)(iv): Electrical equipment had damaged parts that may adversely affect safe operation or mechanical strength of the equipment, such as parts that are broken, bent, cut, or deteriorated by corrosion, chemical action, or overheating.    On or about 5 December 2014, and at times prior thereto, a Robot Coupe food processor being utilized in the kitchen area had cord damage at two separate locations, exposing the employees using it to electrical hazards.
Recent events (2)
  • · I (S) $1350
  • · Z (S) $2700

1910.303 G01 I A

Serious Gravity 1 1 instance 2 exposed
Issued
Feb 5, 2015
Abate by
Mar 25, 2015
Penalty
Initial $2,700 · Current $1,350 Reduced
29 CFR 1910.303(g)(1)(i)(A): For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910.     On or about 5 December 2014, and at times prior thereto, electrical breaker panels in the kitchen area were accessed to turn off or on certain breakers in which the area in front of them did not allow for at least 36 inches of clearance, exposing the employees to an electrical hazard.
Recent events (2)
  • · I (S) $1350
  • · Z (S) $2700

1910.303 G01 II

Serious Gravity 1 1 instance 45 exposed
Issued
Feb 5, 2015
Abate by
Feb 11, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage.  On 5 December 2014, and at times prior thereto, electrical breaker panels in the kitchen area had cardboard boxes and other items stored underneath or on top of 120 volt electrical breaker panels, exposing the employees to a tripping or fire hazard.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340120708.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.