OSHA Inspection: M. LEVIN & CO., INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of M. LEVIN & CO., INC. in 326 PATTISON AVE., PHILADELPHIA, PA 19145 (NAICS 493120). OSHA activity number 340121144.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch M. Levin & CO., INC. — free Get an email when a new federal OSHA severe-injury report for M. Levin & CO., INC. is published. One employer, no account, unsubscribe in one click.
Site address
326 PATTISON AVE.
City
PHILADELPHIA
State
PA
ZIP
19145
Mailing
6700 ESSINGTON AVE. UNITS H2-H5, PHILADELPHIA, PA 19153
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493120
Employees
50
Ownership type
A

5 citations on file for this inspection.

1910.22 A02

Serious Gravity 5 2 instances 5 exposed
Issued
Apr 14, 2015
Abate by
May 1, 2015
Penalty
Initial $2,800 · Current $1,700 Reduced
29 CFR 1910.22(a)(2): Floor(s) of workroom(s) were not maintained in a clean and, so far as possible, a dry condition:    a) M. Levin & Co., Inc., Warehouse - The employer did not ensure that the water on the floor in the ripening room was drained or removed, exposing employees to slip and fall hazards.  Observed on or about 12/5/14.    b) M. Levin & Co., Inc., Warehouse - The employer did not ensure that the water on the floor in the corridor outside of the ripening rooms was drained or removed, exposing employees to slip and fall hazards.  Observed on or about 12/5/14.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $2800

1910.145 C02 I

Serious Gravity 5 2 instances 5 exposed
Issued
Apr 14, 2015
Abate by
Apr 20, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.145(c)(2)(i): Caution signs were not used to warn against potential hazards or to caution against unsafe practices:  a) M. Levin & Co., Inc., Warehouse - Caution signs were not used to warn against potential slip and fall hazards from water on the floor in the corridor outside of the ripening rooms.  Observed on or about 12/5/14.  b) M. Levin & Co., Inc., Warehouse - Caution signs were not used to warn against potential slip and fall hazards from water on the floor in a ripening room.  Observed on or about 12/5/14.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 14, 2015
Abate by
Sep 8, 2015
Penalty
Initial $2,800 · Current $1,600 Reduced
29 CFR 1910.134(c)(1): The Employer did not develop and implement a written respiratory protection program with required worksite-specific procedures and elements for required respirator use:       a) M. Levin & Co., Inc., Warehouse - The employer did not develop and implement a written respiratory protection program with worksite specific procedures for employees required to wear respirators.  Employees wore North model 5400 full facepiece air purifying respirators with N75003L organic vapor/acid gas cartridges with N95 pre-filters when they power washed the ripening rooms.  Observed on or about 12/5/14.
Recent events (2)
  • — I (S) $1600
  • — Z (S) $2800

1910.134 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 14, 2015
Abate by
Sep 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:    a) M. Levin & Co., Inc., Warehouse - The employer did not provide employees with a medical evaluation to determine the employees' ability to wear a respirator before requiring employees to wear full facepiece air purifying respirators when they power washed the ripening rooms.   Employees wore North model 5400 full facepiece air purifying respirators with N75003L organic vapor/acid gas cartridges with N95 pre-filters when they power washed the ripening rooms.  Observed on or about 12/5/14.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 14, 2015
Abate by
Sep 8, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(k)(1): The employer did not provide effective training to employees who were required to use respirators and did not ensure that employees could demonstrate knowledge as required in (k)(1)(I) - (k)(1)(vii):      a) M. Levin & Co., Inc., Warehouse - The employer did not provide employees required to wear respirators with effective training and did not ensure that employees could demonstrate knowledge as required in (k)(1)(I) - (k)(1)(vii).  Employees wore North model 5400 full facepiece air purifying respirators with N75003L organic vapor/acid gas cartridges with N95 pre-filters when they power washed the ripening rooms.  Observed on or about 12/5/14.