BATON ROUGE, LA ·
OSHA Inspection: TURNER INDUSTRIES GROUP, L.L.C.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of TURNER INDUSTRIES GROUP, L.L.C. in EXXONMOBIL BATON ROUGE REFINERY (BRRF) 4045 SCENIC HIGHWAY, BATON ROUGE, LA 70805 (NAICS 324110). OSHA activity number 340121862.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TURNER INDUSTRIES GROUP, L.L.C.
- Site address
- EXXONMOBIL BATON ROUGE REFINERY (BRRF) 4045 SCENIC HIGHWAY
- City
- BATON ROUGE
- State
- LA
- ZIP
- 70805
- Mailing
- 8687 UNITED PLAZA BLVD, BATON ROUGE, LA 70809
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 324110
- Employees
- 950
- Ownership type
- Private (A)
Citations
4 citations on file for this inspection.
1910.147 C04 II
- Issued
- May 15, 2015
- Abate by
- Jun 19, 2015
- Penalty
- Initial $7,000 · Current $7,000
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D): On or about November 27, 2014, at or near 4045 Scenic Highway in Baton Rouge, LA; the employer failed to clearly and specifically outline the methods to be used in controlling hazardous energy, including specific statements of intent, procedural steps for shutdown, procedural steps for locking out, and requirements for testing the effectiveness of energy control measures being used. Because the energy control procedure was too general, each employee engaged in a servicing and/or maintenance activity (i.e., re-spooling, re-threading, inspecting, unjamming, and/or adjusting a drill stem cable) was not adequately protected from the unexpected energization or start-up of associated machines and/or equipment.
Recent events (3)
- · F (S) $7000
- · C (S) $7000
- · Z (S) $7000
1910.147 C06 I
- Issued
- May 15, 2015
- Abate by
- Jun 19, 2015
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: On or about November 27, 2014, at or near 4045 Scenic Highway in Baton Rouge, LA; the employer failed to conduct periodic inspections, at least annually, to correct any deviation or inadequacies in the employers energy control procedure and to prescribe a review of lockout procedures with each authorized employee.
Recent events (3)
- · F (S) $0
- · C (S) $7000
- · Z (S) $7000
1910.147 C06 II
- Issued
- May 15, 2015
- Abate by
- Jun 19, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(ii): The employer did not certify that periodic inspections of the energy control procedures had been performed: On or about November 27, 2014, at or near 4045 Scenic Highway in Baton Rouge, LA; the employer did not certify that periodic inspections of energy control procedures were performed as required by the standard.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.147 D
- Issued
- May 15, 2015
- Abate by
- Jun 19, 2015
- Penalty
- Initial $7,000 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): On or about November 27, 2014, at or near 4045 Scenic Highway in Baton Rouge, LA; the employer did not: a) Isolate a drill stem cable from all energy sources; b) Apply a lockout or tagout device to secure a drill stem cable from all energy sources; and/or c) Verify isolation of the drill stem cable from all energy sources.
Recent events (3)
- · F (S) $0
- · C (S) $7000
- · Z (S) $7000
More inspections at Turner Industries Group, L.L.C.
View Turner Industries Group, L.L.C.'s full OSHA safety record →
More inspections in this industry (NAICS 324110)
More inspections in LA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340121862.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.