BROKEN ARROW, OK ·
OSHA Inspection: ALFA LAVAL INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of ALFA LAVAL INC. in 1201 S. 9TH STREET, BROKEN ARROW, OK 74012 (NAICS 332410). OSHA activity number 340122811.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALFA LAVAL INC.
- Site address
- 1201 S. 9TH STREET
- City
- BROKEN ARROW
- State
- OK
- ZIP
- 74012
- Mailing
- 1201 S. 9TH STREET, BROKEN ARROW, OK 74012
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332410
- Employees
- 250
- Ownership type
- Private (A)
Citations
39 citations on file for this inspection.
1910.22 A01
- Issued
- May 22, 2015
- Abate by
- Sep 15, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms, and service rooms were not kept clean and orderly and in a sanitary condition: The employer does not ensure that work areas are kept clean, exposing employees to fire and tripping hazards. a) This violation was observed on or about November 25, 2014, throughout the facility pneumatic hoses, extension cords, and other work materials were tangled and lying on the floor of immediate employee work areas b) This violation was observed on or about December 8, 2014, in the paint booth, an accumulation of open paint containers/flammable substance containers were present in the floor in the immediate work area of employees c) This violation was observed on or about December 8, 2014, in the metalizing area where dust from the thermal spray process accumulated on elevated surfaces such as, but not limited to the walls and ceilings Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure work areas are kept as clean as the nature of the work allowed.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.23 A05
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.23(a)(5): Every pit and trapdoor floor opening, infrequently used were not guarded by a floor opening cover or protected on all sides by removable standard railings: The employer does not ensure standard railings are used when pits are left uncovered, exposing employees to the hazard of falling into the open pits. This violation was observed on or about December 1, 2014 in a narrow area between the metalizing area and sand blasting bay, employees were exposed to a fall of approximately 47 inches into an uncovered /unguarded pit. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure employees are protected from fall hazards.
Recent events (3)
- · F (S) $4000
- · C (S) $5500
- · Z (S) $5500
1910.23 C01
- Issued
- May 22, 2015
- Abate by
- Dec 15, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.23(c)(1): Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards: The employer does not ensure that employees working above 4 feet are provided with fall protection. a) This violation was observed on or about November 25, 2014 in the structures department at the facility, employees were exposed to a fall of approximately 11 while working on top of a large industrial air conditioner exchanger. b) This violation was observed on or about December 8, 2014 in the structures department at the facility, employees were exposed to a fall of approximately 6 while working on top of a large industrial air conditioner metal frame. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure employees exposed to fall hazards of 4 feet or more are protected.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.26 C02 VII
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $4,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.26(c)(2)(vii): Ladders having defects were not marked or taken out of service until repaired by either the maintenance department or the manufacturer: The employer does not ensure defective ladders are marked or removed from service. a) This violation was observed on or about January 8, 2015, in the metalizing department, exposing employees to the hazard of falls. b) This violation was observed on or about February 3, 2015, in the structures area, exposing employees to the hazard of falls. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure ladders with defect are marked or taken out of service
Recent events (3)
- · F (S) $3000
- · C (S) $4400
- · Z (S) $4400
1910.28 A06
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.28(a)(6): A scaffold damaged or weakened was not immediately repaired: The employer does not ensure mid-rails are provided on a scissor lift that had a broken d-ring which is used to attach a chain style mid-rail. This violation was observed on or about November 25, 2014, in the structures department, exposing employees to the hazard of falls. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure adequate fall protection is provided for employees working on elevated platforms.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.37 A03
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not maintained continuous and free from obstruction. The employer does not ensure a route to an emergency exit door was continuous and free from obstruction. This violation was observed on or about November 25, 2014, in the assembly department, exposing employees to the hazard of smoke inhalation and burn. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure exit are maintained continuous and free from obstruction..
Recent events (3)
- · F (S) $4000
- · C (S) $5500
- · Z (S) $5500
1910.37 B02
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible or marked by a sign reading, EXIT. The employer does not ensure each exit was marked with a sign reading EXIT to identify location of egress in the event of an emergency. This violation was observed on or about November 25, 2014, in the spray booth, exposing employees to the hazard of smoke inhalation and burn. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure each exit is clearly visible and marked by a sign reading, EXIT.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.38 B
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.38(b): An emergency action plan was not in writing, kept in the workplace, and available to employees for review: The employer does not ensure a written emergency action plan is kept in the workplace. This violation was observed on or about November 25, 2014, at the facility, where a written emergency action plan was not kept in the workplace or available to employees for review. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taking to create a written emergency action plan.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.38 D
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.38(d): The employer did not have or maintain an employee alarm system: The employer does not ensure an employee alarm system is maintained. This violation was observed on or about November 25, 2014, at the facility, where employees were exposed to fire and inclement weather hazards. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to implement and maintain an employee alarm system.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.101 B
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $6,600 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in 29CFR 1910.6: The employer does not ensure that stored, compressed gas cylinders are compressed gas cylinders were stored in accordance with Compressed Gas Association Pamphlet P-1-1965. This violation was observed on or about November 25, 2014 when compressed gas cylinders were not secured or provided with protective caps in the assembly area, structures area and throughout the facility. Employees were exposed to fire, explosion and struck by hazards: Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure compressed gas cylinders are stored in accordance with Compressed Gas Association Pamphlet P-1-1965
Recent events (3)
- · F (S) $5000
- · C (S) $6600
- · Z (S) $6600
1910.132 D01
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $4,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE): The employer does not ensure a workplace assessment is conducted to determine if hazards are present, or is likely to be present, which necessitate the use of personal protective equipment (PPE). This violation was observed on or about January 21, 2015, at the facility, where a workplace assessment was not conducted to determine the need for personal protective equipment. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to conduct a workplace assessment to determine the need for personal protective equipment.
Recent events (3)
- · F (S) $3000
- · C (S) $4400
- · Z (S) $4400
1910.133 A01
- Issued
- May 22, 2015
- Abate by
- May 27, 2015
- Penalty
- Initial $4,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: The employer does not ensure employees performing welding wear proper eye protection. This violation was observed on or about December 8, 2014, in the structures area, exposing employees to the hazard of being struck by flying objects and corneal burns. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure the use of personal protective equipment when working on the shop.
Recent events (3)
- · F (S) $3000
- · C (S) $4400
- · Z (S) $4400
1910.146 C01
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: The employer does not ensure a workplace evaluation is conducted to determine if any spaces were permit-required confined spaces. This violation was observed on or about January 21, 2015, at the facility, where a workplace evaluation was not conducted to determine if any spaces were permit-required confined spaces. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to conduct a workplace evaluation to determine if any spaces were permit-required confined spaces.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.147 C06 I
- Issued
- May 22, 2015
- Abate by
- Sep 15, 2015
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed: The employer does not ensure that a periodic inspection of the energy control procedure is conducted at least annually. This violation was observed on or about November 25, 2014, at the facility, exposing employees to the hazard of being caught-in and struck by hazards. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure periodic inspections of the energy control procedure are conducted at least annually to ensure that the procedure and the requirements of this standard are being followed.
Recent events (3)
- · F (S) $4000
- · C (S) $5500
- · Z (S) $5500
1910.157 C01
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $4,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: The employer does not ensure fire extinguishers are free from obstruction and readily accessible: a) This violation was observed on or about November 25, 2014 in the assembly area, a fire extinguisher was blocked by product. b) This violation was observed on or about November 25, 2014 in the structure area, a fire extinguisher was covered and not marked. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure fire extinguishers are mounted, located and identified so that they were readily accessible.
Recent events (3)
- · F (S) $3000
- · C (S) $4400
- · Z (S) $4400
1910.178 L01 I
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $4,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): The employer does not ensure each powered industrial truck operator is competent to operate a powered industrial truck safely. This violation was observed on or about January 21, 2015, in the fin tube area, exposing employees to falling loads and struck-by hazards. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure each powered industrial truck operator is competent to operate a powered industrial truck safely.
Recent events (3)
- · F (S) $3000
- · C (S) $4400
- · Z (S) $4400
1910.178 P01
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(p)(1): Powered industrial truck(s) found to be in need of repair, defective, or in any way unsafe had not been taken out of service until restored to safe operating condition(s): The employer does not ensure forklifts found to be in need of repair, defective, or in any way unsafe are out of service. This violation was observed on or about December 8, 2014, at the facility, exposing employees to falling loads and struck-by hazards. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure forklifts with defects are removed from service until they are restored to a safe operating condition.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.184 E01
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $3,300 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.184(e)(1): Alloy steel sling(s) did not have permanently affixed durable identification stating size, grade, rated capacity, and reach: The employer does not ensure slings have permanently affixed durable identification tags. This violation was observed on or about November 25, 2014, in the fin tube area, exposing employees to the hazard of falling loads. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to identification tags stating size, grade, rated capacity, and reach are affixed to all slings.
Recent events (3)
- · F (S) $3000
- · C (S) $3300
- · Z (S) $3300
1910.184 C06
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.184(c)(6): Slings were not securely attached to their loads: The employer does not ensure slings are securely attached to their loads. This violation was observed on or about February 3, 2015, in the structures area at the facility, exposing employees to the hazard of falling loads. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure slings are securely attached to their loads.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.212 B
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $4,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving: The employer does not ensure machine(s) designed for fixed location(s) were securely anchored to prevent walking or moving, a) This violation was observed on or about December 1, 2014, in the assembly area a Standard press brake was not anchored to the floor, exposing employees to struck-by hazards. b) This violation was observed on or about December 1, 2014, in the louvers area a Niagara punch press was not anchored to the floor, exposing employees to struck-by hazards. c) This violation was observed on or about January 20, 2015, in the louvers area a Rockford press brake was not anchored to the floor, exposing employees to struck-by hazards. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to securely anchored machinery to prevent walking or moving.
Recent events (3)
- · F (S) $3000
- · C (S) $4400
- · Z (S) $4400
1910.215 A04
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $4,400 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eighth inch: The employer does not ensure that the distance between the abrasive wheel and the work rest exceeded one-eighth inch. a) This violation was observed on or about November 25, 2014, in the Headers area, exposing employees to the caught-in and struck-by hazards. b) This violation was observed on or about November 25, 2014, in the Assembly area, exposing employees to the caught-in and struck-by hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure work rests are installed within one-eighth inch of abrasive wheels.
Recent events (3)
- · F (S) $3000
- · C (S) $4400
- · Z (S) $4400
1910.215 B09
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch: The employer does not ensure that the distance between the grinding wheel periphery and the adjustable tongue or the end of the peripheral member at the top does not exceed one-fourth inch in the maintenance shop. a) This violation was observed on or about November 25, 2014, in the Headers area, exposing employees to the caught-in and struck-by hazards. b) This violation was observed on or about November 25, 2014, in the Assembly area, exposing employees to the caught-in and struck-by hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure the distance between the grinding wheel periphery and the adjustable tongue does not exceed one-fourth inch
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.217 B04 I
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals: The employer does not ensure a pedal mechanism on mechanical power press was protected to prevent unintended operation. This violation was observed on or about November 25, 2014, in the structures area, exposing employees to struck-by hazards on a Steelweld mechanical punch press. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure the foot pedal will be guarded in order to prevent accidental start-up.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.217 E01 I
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $3,300 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment: The employer does not ensure a program of periodic and regular inspections of mechanical power and punch presses were established and followed. This violation was observed on or about November 25, 2014, at the facility, exposing employees to struck-by hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to develop a mechanical power press inspection program.
Recent events (3)
- · F (S) $3000
- · C (S) $3300
- · Z (S) $3300
1910.219 D01
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley which were seven (7) or less from the floor level were not fully enclosed by guards: The employer does not ensure that pulley(s) seven feet or less from the floor level are fully enclosed by guards. This violation was observed on or about February 3, 2015, in the compressor room of the fin tube area, where employees were exposed caught-in hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure pulley(s) 42 inches or less from the floor level are fully enclosed
Recent events (3)
- · F (S) $4000
- · C (S) $5500
- · Z (S) $5500
1910.219 E03 I
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o): The employer does not ensure that vertical or inclined pulley(s) seven feet or less from the floor level are fully enclosed by guards. This violation was observed on or about February 3, 2015, in the compressor room of the fin tube area, where employees were exposed caught-in hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure pulley(s) 42 inches or less from the floor level are fully enclosed.
Recent events (3)
- · F (S) $0
- · C (S) $0
- · Z (S) $0
1910.243 B02
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $3,300 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.243(b)(2): Hose and hose connections used for conducting compressed air to utilization equipment were not designed for the pressure and service to which they are subjected. The employer does not ensure that hose connections used for conducting compressed air to utilization equipment are designed for the use. This violation was observed on or about November 25, 2014, in the structures area, exposing employees to the struck-by hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure hose clamps are not used on pneumatic lines
Recent events (3)
- · F (S) $3000
- · C (S) $3300
- · Z (S) $3300
1910.243 C01
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4): The employer does not ensure portable hand grinders were provided with safety guards. a) This violation was observed on or about November 25, 2014, in the structures area, exposing employees to the hazard of lacerations and amputations. b) This violation was observed on or about November 25, 2014, in the assembly area, exposing employees to the hazard of lacerations and amputations. c) This violation was observed on or about November 25, 2014, in the headers area, exposing employees to the hazard of lacerations and amputations. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure all portable power tools are properly guarded.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.252 B02 III
- Issued
- May 22, 2015
- Abate by
- Aug 15, 2015
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.252(b)(2)(iii): Workers and other persons adjacent to the welding area were not protected from the rays by noncombustible or flameproof screens or shields: The employer does not ensure workers and other persons adjacent to the welding area were protected from the rays. a) This violation was observed on or about November 25, 2014, in the structures department at the facility, exposing adjacent employees to the hazard of flash burns. b) This violation was observed on or about November 25, 2014, in the assembly department at the facility, exposing adjacent employees to the hazard of flash burns Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure workers and other persons adjacent welding areas are protected from the rays.
Recent events (3)
- · F (S) $4000
- · C (S) $5500
- · Z (S) $5500
1910.303 B02
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled equipment was not used or installed in accordance with any instructions included in the listing or labeling: The employer does not ensure electrical equipment are used or installed in a manner in which they are intended: a) This violation was observed was on or about November 25, 2014 in multiple locations at the facility, household power taps were not approved for use in heavy manufacturing environments, exposing employees to the electrical hazards. b) This violation was observed was on or about November 25, 2014 in multiple locations at the facility, pendant boxes intended for permanent installation were used on the ends of flexible cords, exposing employees to electrical hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure electrical equipment is being used in accordance with their intended use.
Recent events (3)
- · F (S) $4000
- · C (S) $5500
- · Z (S) $5500
1910.303 G01
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $3,300 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: The employer does not ensure sufficient access and working space around electrical panels was maintained. This violation was observed on or about November 25, 2014, at the facility, exposing employees to electrical hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure sufficient access is maintained about all electric equipment.
Recent events (3)
- · F (S) $3000
- · C (S) $3300
- · Z (S) $3300
1910.303 B07
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
29 CFR 1910.303(b)(7): Electric equipment was not installed in a neat and workmanlike manner. The employer does not ensure that electrical equipment is installed in a neat and workmanlike manner. This violation was observed on or about November 25, 2014, in the structures area, where flexible metal conduit was disconnected from an enclosure leaving internal conducts exposed and subjected to damage. Employees were exposed to electrical hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure electrical equipment is installed neat and workmanlike.
Recent events (3)
- · F (S) $4000
- · C (S) $5500
- · Z (S) $5500
1910.305 B01 II
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $5,500 · Current $4,000 Reduced
General-duty citation text
1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings were not effectively closed: The employer does not ensure that unused openings in electrical disconnect panels are effectively closed. This violation was observed on or about November 25, 2014, in the structure area, assembly area 1 and metalizing area, exposing employees to electrical hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure that unused openings in cabinets, boxes, and fittings are effectively closed
Recent events (3)
- · F (S) $4000
- · C (S) $5500
- · Z (S) $5500
1910.305 B02
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.305(b)(2): All junction boxes and each outlet box were not provided with an approved cover, faceplate, or fixture canopy: The employer does not ensure all junction boxes and each outlet box are provided with an approved cover or faceplate. This violation was observed on or about November 25, 2014 in the structure area, fin tube shop and metalizing area. Employees are exposed to electrical hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken ensure that all junction boxes and outlet boxes have covers, faceplates, or fixture canopies.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.305 G01 IV A
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $3,300 · Current $3,000 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: The employer does not ensure that extension cords (flex wiring) are not used as a substitute for fixed wiring. This violation was observed on or about November 25, 2014, throughout the facility, exposing employees to electrical hazards. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure that all flexible cords and/or cables are not used as a substitute for fixed wiring.
Recent events (3)
- · F (S) $3000
- · C (S) $3300
- · Z (S) $3300
1910.333 B02
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $7,000 · Current $5,000 Reduced
General-duty citation text
29 CFR 1910.333(b)(2): While an employee was exposed to contact with parts of fixed electric equipment or circuits which were deenergized, the circuits energizing the parts were not locked out or tagged or both in accordance with the requirements of this paragraph (b) of 29 CFR 1910.333(b)(2):: The employer does not ensure that deenergized electric circuits are locked and tagged out prior to work on the equipment. This violation was observed on or about November 25, 2014, in the structures area on CNC machine #5 exposing. Employees are exposed to electrical hazards. Pursuant to 29 CFR 1903.19, within (10) calendar days of the date of this citation, the employer must submit documentation describing the steps that is taking to ensure lockout devices are affixed in a manner that held the energy isolating device in a safe or off position.
Recent events (3)
- · F (S) $5000
- · C (S) $7000
- · Z (S) $7000
1910.212 A01
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $70,000 · Current $70,000
General-duty citation text
29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: The employer does not ensure all equipment used at the facility is provided with proper machine guarding, exposing employees to the hazard of amputation hazards. a) This violation was observed on or about November 25, 2014, where a Doall horizontal band saw in the structures area is not properly guarded. b) This violation was observed on or about November 25, 2014, where a Roll-in vertical band saw in the structures area is not properly guarded. c) This violation was observed on or about November 25, 2014, where the Niagra brand hydraulic press brake in the fintube area is not properly guarded. d) This violation was observed on or about November 25, 2014, where the Steelweld brand mechanical press brake in the structures are is not properly guarded. e) This violation was observed on or about November 25, 2014, where the Standard brand hydraulic press brake in the structures is not properly guarded. f) This violation was observed on or about November 25, 2014, where the Pacific brand hydraulic press brake in the structures is not properly guarded. Alfa Laval, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 314341223, citation number 1, item number 2, and was affirmed as a final order on May 25, 2010, with a final abatement date of June 25, 2010, with respect to a workplace hazard at 111 Parker Street Newburyport, MA 01950. Alfa Laval, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.212(a)(1), which was contained in OSHA inspection number 314245945, citation number 2, item number 1, and was affirmed as a final order on August 22, 2011, with a final abatement date of August 31, 2011, with respect to a workplace hazard at 300 Chestnut Street Lykens, PA 17048. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure machine guarding is provided to protect operator(s) and other employees from hazard(s) created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.
Recent events (3)
- · F (R) $70000
- · C (R) $70000
- · Z (R) $70000
1910.147 C04 I
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $38,500 · Current $0 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: The employer does not ensure procedures were developed, documented and utilized for the control of potentially hazardous energy. This violation was observed on or about November 25, 2014, throughout the facility, where employees are exposed to the hazard of being caught-in or struck by moving parts as a result of unexpected re-energizing of equipment. Alfa Laval, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.147(c)(4)(ii), which was contained in OSHA inspection number 314341223, citation number 1, item number 1, and was affirmed as a final order on May 25, 2010, with a final abatement date of June 25, 2010, with respect to a workplace hazard at 111 Parker Street Newburyport, MA 01950. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure procedures are developed, documented and utilized for the control of potentially hazardous energy.
Recent events (3)
- · F (R) $0
- · C (R) $38500
- · Z (R) $38500
1910.253 B04 III
- Issued
- May 22, 2015
- Abate by
- Jun 9, 2015
- Penalty
- Initial $38,500 · Current $38,500
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: The employer does not ensure that compressed gas cylinders of oxygen are at least 20 feet from fuel-gas cylinders and highly combustible materials such as oil. This violation was observed on or about November 25, 2014, in an outside cylinder storage area, exposing employees to explosion and fire hazards resulting from incompatibility of hazardous materials. Alfa Laval, Inc. was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1910.253(b)(4)(iii), which was contained in OSHA inspection number 314245945, citation number 1, item number 3, and was affirmed as a final order on May 25, 2010, with a final abatement date of June 25, 2010, with respect to a workplace hazard at 111Parker Street Newburyport, MA 01950. Pursuant to 29 CFR 1903.19, within ten (10) calendar days of the date of this citation, the employer must submit documentation describing the steps taken to ensure that all compressed gas cylinder of oxygen are at least 20 feet from fuel-gas cylinders and highly combustible materials such as oil. . .
Recent events (3)
- · F (R) $38500
- · C (R) $38500
- · Z (R) $38500
More inspections at Alfa Laval INC.
View Alfa Laval INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332410)
More inspections in OK
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 340122811.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.