OSHA Inspection: STAINLESS FABRICATION INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of STAINLESS FABRICATION INC in 4455 W. KEARNEY, SPRINGFIELD, MO 65803 (NAICS 332313). OSHA activity number 340123967.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Stainless Fabrication INC — free Get an email when a new federal OSHA severe-injury report for Stainless Fabrication INC is published. One employer, no account, unsubscribe in one click.
Site address
4455 W. KEARNEY
City
SPRINGFIELD
State
MO
ZIP
65803
Mailing
4455 W. KEARNEY, SPRINGFIELD, MO 65803
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332313
Employees
180
Ownership type
A

5 citations on file for this inspection.

1910.215 B09

Other-than-serious 1 instance 1 exposed
Issued
Dec 16, 2014
Abate by
Jan 13, 2015
Penalty
Initial $2,700 · Current $1,400 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    On or about November 18, 2014 at the Stainless Fabrication facility- employees were exposed to a struck by hazard from an 8 inch Bench Grinder, in the Maintenance Shop, which had tongue guards that were improperly adjusted in excess of one-fourth inch.
Recent events (2)
  • — I (O) $1400
  • — Z (S) $2700

1910.253 B04 III

Other-than-serious 2 instances 180 exposed
Issued
Dec 16, 2014
Penalty
Initial $4,500 · Current $1,000 Reduced
29 CFR 1910.253(b)(4)(iii) Oxygen cylinders in storage were not separated from fuel-gas cylinders a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hours.      On or about November 18, 2014 at the Stainless Fabrication facility- employees in the main shop floor were exposed to a fire hazard from gas cylinders which were stored in direct contact with oxygen cylinders.      Abatement certification is not required for this item:
Recent events (2)
  • — I (O) $1000
  • — Z (S) $4500

1910.303 F02

Other-than-serious 2 instances 2 exposed
Issued
Dec 16, 2014
Abate by
Jan 13, 2015
Penalty
Initial $3,600 · Current $1,000 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:     On or about November 18, 2014 at the Stainless Fabrication Facility- employees were exposed to serious injuries, in that the employer had not marked and identified the breakers in the electrical panel located in the NE Corner of the warehouse.       Abatement certification is required for this item;
Recent events (2)
  • — I (O) $1000
  • — Z (S) $3600

1910.304 G05

Deleted Serious Gravity 5 3 instances 2 exposed
Issued
Dec 16, 2014
Abate by
Jan 13, 2015
Penalty
Initial $3,600 · Current $0 Reduced
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous and effective:   On or about November 18, 2014 at the Stainless Fabrication Facility- employees were exposed to Electrical Shock injuries, in that the electrical cords that power the floor fans in use did not have a ground pin to ensure the path to ground was permanent, continuous and effective.               Abatement certification is required for this item;
Recent events (2)
  • — I (S) $0
  • — Z (S) $3600

1910.305 G02 III

Other-than-serious 1 instance 2 exposed
Issued
Dec 16, 2014
Abate by
Jan 13, 2015
Penalty
Initial $3,600 · Current $1,000 Reduced
29 CFR 1910.305(g)(2)(iii):  Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws:        On or about November 18, 2014 at the Stainless Fabrication facility- 110V flexible cable had pulled loose from its attachment point to a portable outlet box leaving the cable attached to the device by its internal conductors.      Abatement certification is required for this item.
Recent events (2)
  • — I (O) $1000
  • — Z (S) $3600

View Stainless Fabrication INC's full OSHA safety record →