WILKES BARRE, PA —
OSHA Inspection: BLOOMSBURG METAL COMPANY LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BLOOMSBURG METAL COMPANY LLC in 610 NORTH PENNSYLVANIA AVENUE, WILKES BARRE, PA 18705 (NAICS 423510). OSHA activity number 340124312.
Where did this inspection happen?
- Establishment
- BLOOMSBURG METAL COMPANY LLC
- Site address
- 610 NORTH PENNSYLVANIA AVENUE
- City
- WILKES BARRE
- State
- PA
- ZIP
- 18705
- Mailing
- PO BOX 450, WILKES BARRE, PA 18703
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423510
- Employees
- 28
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $1607.00 · Current $1205.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed: a) Building 1 and Rear Building: The employer did not conduct a periodic inspection of the energy control procedures at least annually, on or about December 9, 2014. Abatement Certification Required.
Recent events (2)
- — I (S) $1205.25
- — Z (S) $1607
1910.147 C07 IV
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date: a) Building 1 and Rear Building: The employer did not certify that employee training had been accomplished and kept up to date, on or about December 12, 2014. Abatement Certification Required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.253 B04 III
- Issued
- Penalty
- Initial $1607.00 · Current $1205.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one half hour: a) Rear Building: Oxygen cylinders were being stored with acetylene cylinders and in near proximity to propane cylinders, as observed on or about December 9, 2014. Abatement Observed During Inspection.
Recent events (2)
- — I (S) $1205.25
- — Z (S) $1607
1910.305 G01 IV
- Issued
- Abate by
- Penalty
- Initial $1607.00 · Current $1205.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv): a) Sheet Bay, Building 1: Flexible electrical cords for the water cooler and refrigerator were routed from the Aluminum Bay through a hole in the metal door, as observed on or about December 9, 2014. Abatement Certification Required.
Recent events (2)
- — I (S) $1205.25
- — Z (S) $1607
1910.303 G01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Rear Building: Lumber was in storage in front of electrical disconnect equipment limiting safe access and operation, as observed on or about December 9, 2014. Abatement Observed During Inspection.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.37 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(b)(2): Each exit was not clearly visible and marked by a sign reading "Exit": a) Building 1: The rear emergency exit door, located in the Sheet Bay, was not marked with a sign reading "EXIT", as observed on or about December 9, 2014. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.157 G02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.157(g)(2): The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter: a) Building 1 and Rear Building: The employer did not provide an educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting, on or about December 12, 2014. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.184 E03 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.184(e)(3)(ii): Records of the most recent month in which each alloy steel chain sling was thoroughly inspected were not available for examination: a) Building 1 and Rear Building: The employer did not maintain a record of the most recent month in which each alloy steel chain sling was thoroughly inspected, on or about December 12, 2014. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a) Building 1 and Rear Building: The employer did not develop or maintain a written hazard communication program for the facility, on or about December 12, 2014. Abatement Certification Required.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at BLOOMSBURG METAL COMPANY LLC
WILKES BARRE, PA—2013-08-20 00:00:00
BLOOMSBURG METAL COMPANY LLC
View BLOOMSBURG METAL COMPANY LLC's full OSHA safety record →
More inspections in this industry (NAICS 423510)
NORTH CHARLESTON, SC—2026-07-16 00:00:00
77576 - ALLIED CRAWFORD STEEL
HAMMOND, IN—2026-07-07 00:00:00
JUPITER ALUMINUM CORPORATION
BETTENDORF, IA—2026-07-06 00:00:00
A09CS000011UWT9AAA - OLYMPIC STEEL, INC.
GREELEY, CO—2026-07-01 00:00:00
NORFOLK IRON & METAL COMPANY
OAKLAND, CA—2026-06-30 00:00:00
TAV HOLDINGS, INC.
More inspections in PA
COLUMBIA, PA—2026-07-17 00:00:00
FOX TAPPING INC.
COLUMBIA, PA—2026-07-17 00:00:00
COLUMBIA WATER CO
WILKES BARRE, PA—2026-07-17 00:00:00
NEW ENTERPRISE STONE & LIME CO., INC.
PHILADELPHIA, PA—2026-07-16 00:00:00
MUKHLEEN GERNAROS PIZZA LLC DBA GENARO'S PIZZERIA AND STEAKS
PHILADELPHIA, PA—2026-07-16 00:00:00
CENTER CITY CONSTRUCTION AND DEVELOPMENT, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340124312.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.