BRONX, NY —
OSHA Inspection: TOLTECAS AUTO ELECTRIC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TOLTECAS AUTO ELECTRIC in 12 EAST CLARKE PLACE, BRONX, NY 10452 (NAICS 336322). OSHA activity number 340125798.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOLTECAS AUTO ELECTRIC
- Site address
- 12 EAST CLARKE PLACE
- City
- BRONX
- State
- NY
- ZIP
- 10452
- Mailing
- 12 EAST CLARKE PLACE, BRONX, NY 10452
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336322
- Employees
- 4
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.23 A01
- Issued
- Dec 24, 2014
- Abate by
- Jan 29, 2015
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.23(a)(1): Every stairway floor opening was not guarded by a standard railing constructed in accordance with paragraph (e) of this section on all exposed sides (except at the entrance to the stairway): On or about 12/9/14 Location:12 E. Clarke Pl, NY 10452 a) Floor opening that connects the 1st floor to the basement was not protected exposing the employees to falls.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.37 B01
- Issued
- Dec 24, 2014
- Abate by
- Jan 29, 2015
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.37(b)(1): Each exit route was not adequately lighted so that employees with normal vision could see along the exit route: On or about 12/9/14 Location:12 E. Clarke Pl, NY 10452 a) Exit route was not adequately lighted exposing the employees to be delayed in the event of fire or other emergency.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.215 A04
- Issued
- Dec 24, 2014
- Abate by
- Jan 14, 2015
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch: On or about 12/9/14 Location:12 E. Clarke Pl, NY 10452 a) The work rests on the abrasive wheel grinder was missing.
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.215 B09
- Issued
- Dec 24, 2014
- Abate by
- Jan 14, 2015
- Penalty
- Initial $1,600 · Current $1,200 Reduced
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch: On or about 12/9/14 Location:12 E. Clarke Pl, NY 10452 a) The tongue guard was missing on the abrasive wheel grinder
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
1910.303 B01
- Issued
- Dec 24, 2014
- Abate by
- Jan 29, 2015
- Penalty
- Initial $1,200 · Current $576 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: On or about 12/9/14 Location:12 E. Clarke Pl, NY 10452 a) The on/off switch on the bench top grinder was missing its faceplate allowing dust and debris to enter the switch.
Recent events (2)
- — I (S) $576
- — Z (S) $1200
1910.305 B01 II
- Issued
- Dec 24, 2014
- Abate by
- Jan 14, 2015
- Penalty
- Initial $2,000 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: On or about 12/9/14 Location:12 E. Clarke Pl, NY 10452 a) A 120 volt circuit breaker panel in the back of the first floor next to the blaster machine had two missing breakers exposing live electrical buses and wiring.
Recent events (2)
- — I (S) $1500
- — Z (S) $2000
1910.305 B02 I
- Issued
- Dec 24, 2014
- Abate by
- Jan 29, 2015
- Penalty
- Initial $1,600 · Current $1,500 Reduced
General-duty citation text
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: On or about 12/9/14 Location:12 E. Clarke Pl, NY 10452 a) A junction box located on the back wall of the basement did not have a cover plate exposing live electrical wiring. b) A junction box located on the partition wall of the basement did not have a cover plate exposing live electrical wiring. c) A junction box located on the east wall of the 1st floor did not have a cover plate exposing live electrical wiring.
Recent events (2)
- — I (S) $1500
- — Z (S) $1600
More inspections at Toltecas Auto Electric
View Toltecas Auto Electric's full OSHA safety record →
More inspections in this industry (NAICS 336322)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 340125798.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.