OSHA Inspection: ANODIZERS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ANODIZERS, INC. in 504 E 46TH ST, GARDEN CITY, ID 83714 (NAICS 332813). OSHA activity number 340126887.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Anodizers, INC. — free Get an email when a new federal OSHA severe-injury report for Anodizers, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ANODIZERS, INC.
Site address
504 E 46TH ST
City
GARDEN CITY
State
ID
ZIP
83714
Mailing
504 E 46TH ST, GARDEN CITY, ID 83714
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332813
Employees
14
Ownership type
A

6 citations on file for this inspection.

1910.242 B

Serious Gravity 1 1 instance 2 exposed
Issued
Jan 23, 2015
Abate by
Feb 19, 2015
Penalty
Initial $1,200 · Current $600 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:  (a) Shop: On or about December 9, 2014 and at times prior thereto, employees were utilizing shop air at between 110psi and 125psi to dry parts.  Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

1910.134 C01

Other-than-serious 1 instance 2 exposed
Issued
Jan 23, 2015
Abate by
Feb 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use:  (a) Anodizing Line: On or about December 9, 2014 and at times prior thereto, where employees are required to wear tight-fitting, 3M respirators, the employer did not have a written respiratory protection program implemented at the workplace.     Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 E01

Other-than-serious 2 instances 2 exposed
Issued
Jan 23, 2015
Abate by
Feb 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace:  (a) Anodizing Line: On or about December 9, 2014 and at times prior thereto, employees required to wear respirators had not been medically evaluated prior to use.        NOTE: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 F01

Other-than-serious 2 instances 2 exposed
Issued
Jan 23, 2015
Abate by
Feb 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT):  (a) Anodizing Line: On or about December 9, 2014 and at times prior thereto, employees required to wear respirators had not been fit tested prior to use.         Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 G01 I A

Other-than-serious 1 instance 1 exposed
Issued
Jan 23, 2015
Abate by
Feb 19, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  (a) Anodizing Line: On or about December 9, 2014 and at times prior thereto, an employee required to wear a half face elastomeric 3M respirator had a beard that may interfere with the seal of the respirator.     Note: Abatement certification IS required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1200 F06 I

Other-than-serious 4 instances 2 exposed
Issued
Jan 23, 2015
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(f)(6)(i): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the information required by 29 CFR 1910.1200(f)(1)(i) through 29 CFR 1910.1200(f)(1)(v).  (a) Anodizing Line: On or about December 9, 2014 and at times prior thereto, several dip tanks including, but not limited to Gold Chromate tank, were not labeled.  Note: Abatement certification IS NOT required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Anodizers, INC.'s full OSHA safety record →